Characters shall be uppercase or lowercase or a combination of both.
Search Results "Patient Toilet Room"
Commonly Searched Documents
-
11B-703.5.2 Case
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
4.35.4 Bench
Every accessible dressing room shall have a 24 in by 48 in (610 mm by 1220 mm) bench fixed to the wall along the longer dimension....
-
224.2 Guest Rooms with Mobility Features
Facilities on a common site that each have 50 or fewer guest rooms may be combined for the purposes of determining the required number of accessible rooms and type of accessible bathing...
-
5.8.3 Breast Platform Recommendations
platform (see 5.8.2 Knee and Toe Clearance Recommendations under Breast Platforms), the height of the breast platform is also critical to ensuring that mammography equipment is accessible to patients...
- Young Equipment Sales Vinyl Bleacher End Closures
-
F224.2 Guest Rooms with Mobility Features
In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table F224.2....
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
Accessible Meeting Location
Accessible Meeting Location People attending a meeting are concerned about where to find parking, the building entrance, the meeting room, and restrooms....
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
806.2.2 Exterior Spaces
Exterior spaces, including patios, terraces and balconies, that serve the guest room shall be accessible....
-
806.2.2 Exterior Spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
Personal Assistants and Service Animals
Personal Assistants Ensure seating plans include room for each assistant, both within meeting rooms and meal service areas....
-
Signage
Signage Common Problem: For permanent rooms and spaces, identification signage is mounted in the wrong location and cannot be read by persons who are blind or have low vision....