Elements that have not been altered in existing facilities on or after March 15, 2012 and that comply with the corresponding technical and scoping specifications for those elements in either...
Search Results "Medical Care Facility"
-
§ 35.150(b)(2)(i) Safe harbor
-
11B-232.2.1.1 Beds
In cells having more than 25 beds, at least 5 percent of the beds shall have clear floor space complying with Section 11B-807.2.3.
-
Beds: ADA Standard Section 232.2.1.1
Section 232.2.1.1 covers scoping requirements in the current ADA Standards for beds.
-
11B-232.2.1.1 Beds
In cells having more than 25 beds, at least 5 percent of the beds shall have clear floor space complying with Section 11B-807.2.3.
-
68.30(3) Van Accessible Parking at Garages Constructed Prior to April 1994
additional surface parking is provided, the required van accessible parking spaces shall be located on a surface lot in closest proximity to the accessible public entrance serving the facility...
-
11B-201.4 Construction Support Facilities
When provided, toilet and bathing facilities serving construction support facilities shall comply with 11B-213....
-
11B-201.4 Construction Support Facilities
When provided, toilet and bathing facilities serving construction support facilities shall comply with 11B-213....
-
11B-201.4 Construction Support Facilities
When provided, toilet and bathing facilities serving construction support facilities shall comply with 11B-213....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.2.4.2 Other Equipment
Wheelchair spaces beneath diagnostic equipment other than breast platforms shall comply with M303.2.4.2.
-
11B-805.4.2 Equipment
Clear space complying with Section 11B-305.2 shall be provided as required for specific equipment.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....
-
M301 Diagnostic Equipment used by Patients in a Supine, Prone, or Side-lying Position (Section-by-Section Analysis)
M301 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a supine, prone, or side-lying position such as, examination tables, imaging...
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches. Rationale...
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
The Access Board is considering adding exceptions in the final standards to the minimum width in M303.2.2 and the minimum depth in M303.2.3 for diagnostic equipment with wheelchair...
-
Chapter M1 Application and Administration
[See subsections ...]
-
11B-805.4.2 Equipment
Clear space complying with Section 11B-305.2 shall be provided as required for specific equipment.