Cross ventilation for fresh air while sleeping. Touch controls on all cabinets and doors (no knobs) Touch controls on metal lamps (master bedroom) Touch...
Search Results "Critical Care Patient Room"
-
Master Bedroom
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
Chapter M1 Application and Administration
[See subsections ...]
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the...
-
Shower and Sauna Doors in Transient Lodging Facilities
Section 9.4 of the 1991 Standards and section 206.5.3 of the 2010 Standards both require passage doors in transient lodging guest rooms that do not provide mobility features to provide at...
-
11B-226.4 Baby diaper changing station
Baby diaper changing stations shall comply with Sections 11B-309 and 11B-902. Baby diaper changing stations when deployed shall not obstruct the required width of an accessible route...
-
11B-806.3.1 Alarms
Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4. [2010 ADA Standards] 806.3.1...
-
11B-806.3.1 Alarms
Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4. [2010 ADA Standards] 806.3.1...
-
11B-226.4 Baby diaper changing station
Baby diaper changing stations shall comply with Sections 11B-309 and 11B-902. Baby diaper changing stations when deployed shall not obstruct the required width of an accessible route...
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
18(a)
least one suite (if the hotel has more than one suite), one room with one bed, one room with two beds, and one room with a premium view (if the hotel offers more than one room with a premium...
-
Can doors swing into required clear floor or ground space?
bathing facilities (except those that are single user where wheelchair space beyond the door swing is provided) (603.2.3) clear floor space required at benches in saunas and steam rooms...
- Access Board: Multi User Toilet Room Layout
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section....
-
Sec.36.304(c)(3)
(3) Third, a public accommodation should take measures to provide access to restroom facilities. These measures include, for example, removal of obstructing furniture or vending...
-
Vanity Counter Space
Vanity Counter Space. Section 806.2.4.1 of the 2010 Standards requires that if vanity countertop space is provided in inaccessible transient lodging guest bathrooms, comparable...
-
Alternative formats
□ Ensure hard copy information is/can be provided in alternative formats such as large print, disks, or Braille when requested in advance of the meeting or event. Contact the USDA...
-
11B-809.4 Toilet facilities and bathing facilities
At least one bathroom shall comply with Section 11B-603. No fewer than one of each type of fixture provided within the bathroom shall comply with applicable requirements of Sections...
-
Overlapping Wheelchair Turning Space
A provision in section 806.2.6 prohibiting beds from overlapping wheelchair turning space has been removed for consistency with specifications for such space in section 304, as...
-
Question 8
YES/NO 8. Are the lower edges of all objects that hang over the sidewalks or walkways (e.g., banners, strings of lights) 80 inches or more above the...
-
809.4 Toilet Facilities and Bathing Facilities
At least one bathroom shall comply with 603. No fewer than one of each type of fixture provided shall comply with applicable requirements of 603 through 610. Toilet and bathing...