Chapter 4: Implications for standards and design
-
T503.3 Steps at Front Doorways
The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
- Access Board: Obstructed Side Reach
-
4.26.4 Eliminating Hazards
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
4.26.4 ELIMINATING HAZARDS
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
§ 38.159(c)(2) Ramp surface
(2) Ramp surface....
-
1002.6.3 Wheelchair Storage Space
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
1002.6.3 Wheelchair Storage Space
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
1017.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1017.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1017.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
- Pilot Rock RT Series End Accessible Recycled Plastic Picnic Table
-
1. Sloped Surfaces
Sloped Surfaces Measuring the slope of a ramp, parking space, walkway, or other ground or floor surface is important to identify whether the surface is accessible....
-
2.5.4 Slope
Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper than 1:48 (2 percent) in any direction. ...
-
Section F: Voting Area
_______________________ Location name:______________________ F Within the Voting Area Yes No N/A Comments/Remedies F1 Are floor surfaces...
-
Cross Slope (R302.6) (Section-by-Section Analysis)
In exterior environments, a maximum cross slope of 2 percent is generally accepted as adequate to allow water to drain off paved walking surfaces....
- Figure 505.6 Horizontal Projections Below Gripping Surface – Drawing from the U.S. Access Board
- Smith System Lift Desk Work Surface with Crank
- Husky 10" Multi-Function Standard Digital Level
-
1c
c. Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above? [ADA...
-
A4.21.1 GENERAL
Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within...
-
4.21.2 Size and Clearances
4.21.2 Size and Clearances. Minimum guidelines for roll-in shower stalls are based on residential size fixtures (30" x 60" minimum or the space used by a standard residential...
-
Avoid the extremes of surface reflectivity and contrast (slides 11 and 13)
We don’t have to have highly reflective surfaces that will still reflect light but spread it, diffuse that light instead of pinpoint reflections....
-
Exercise Machines and Equipment
Section 1004.1 of the 2010 Standards requires a clear floor space “positioned for transfer or for use by an individual seated in a wheelchair” to serve at least one of each type of exercise...