Clear Floor Space [4.34.2] and Reach Ranges [4.34.3] Either a forward approach or a parallel approach to the ATM must be provided....
Search Results "Electric Vehicle Charging Space"
Commonly Searched Documents
-
Clear Floor Space [4.34.2] and Reach Ranges [4.34.3]
-
4.6.5 Slope
The slope of the clear floor or ground space required by section 4.6.4 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
4.1.5 Slope
The slope of the surface of the clear floor or ground space around a picnic table shall not exceed 1:48 (2 percent) in any direction. Exception....
-
1016.4 Passing Spaces
Outdoor recreation access routes with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 1016.4 at intervals of 200 feet (61 m) maximum. ...
-
1016.4 Passing Spaces
Outdoor recreation access routes with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 1016.4 at intervals of 200 feet (61 m) maximum....
-
802.1.4 Approach
Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. Advisory 802.1.4 Approach....
-
11B-802.1.4 Approach
Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. [2010 ADAS] Advisory 802.1.4 Approach. ...
-
802.1.4 Approach
Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. Advisory 802.1.4 Approach....
-
11B-802.1.4 Approach
Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. [2010 ADAS] Advisory 802.1.4 Approach....
-
11B-802.1.4 Approach
Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. Advisory 11B-802.1.4 Approach....
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
802.1.4 Approach
Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. [ECTCR UFAS 4.33.3, 4.2.4.2, Fig. 46(b)] Advisory 802.1.4 Approach....
-
1134A.4 Sufficient maneuvering space
1134A.4 Sufficient maneuvering space. ...
-
11B-803.2 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-803.2 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-803.2 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
Can accessible spaces be parallel instead of perpendicular?
The Standards do not specifically require that accessible spaces be perpendicular instead of parallel, but perpendicular parking spaces are preferred at facilities located on sites because...
-
§ 38.159(b)(6) Platform surface
(6) Platform surface. The platform surface shall be free of any protrusions of 1/4 inch (6.5 mm) high and shall be slip resistant. The platform shall have a minimum clear width of 28...
-
§ 38.159(c)(2) Ramp surface
(2) Ramp surface. The ramp surface shall be continuous and slip resistant; shall not have protrusions from the surface greater than 1/4 inch (6.5 mm) high; shall have a clear width...
-
§ 38.83(b)(6) Platform surface
(6) Platform surface. The lift platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant. The lift platform shall have a minimum clear width of...
-
Clear floor space beside or between beds must be 36" wide
Remember that because the clear floor space required by 806.2.3 will be deeper than 24" to end up beside or between the beds where it will be usable, it will be in an alcove that is at least...