(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided...
Search Results "Door Surface"
-
§ 38.93(a)(1)
-
11B-1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951....
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
- Hager Companies 5300 Series - Heavy Duty Surface Door Closer
-
Clear Ground Space [1013.2]
The surface of the clear ground space must be firm and stable, but must also accommodate the use of tent stakes or other devices to secure the tent....
- ADAEZ Pro Plus Automatic Door Opener Installation Video
-
Accessible - Changes in Level
Accessible - Changes in Level: Changes in level up to 1/4" may be vertical and without edge treatment. Changes in level between 1/4" and 1/2" shall be beveled with a slope no...
-
Circular Cross Section: ADA Standard Section 505.7.1
Section 505.7.1 covers the current ADA Standards for the circular cross section of handrail gripping surfaces.
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
Surfaces. In accordance with the ADA Standards, ramps and approaches shall be designed so that water will not accumulate on walking surfaces. 3. Curb Ramps....
-
1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
Use Zones: ADA Standard Section 1008.2.6.2
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1)....
- Norton Surface Mounted Medium Duty 8000 Series Door Closer
-
1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
4(4)
(4) Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch....
-
1015.6 Slope
This section requires the slope of the surface of the clear ground space and turning space to not be steeper than 1:48 in any direction....
-
General: ADA Standard Section 240.1
Section 240.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for play areas.
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2....
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1....
-
M301.2.1 Transfer Surface Height
Many X-Ray systems have imaging components such as X-Ray tubes, high voltage generators, and/or detectors located under the table (transfer surface)....
-
Stabila, Inc. Magnetic TECH Digital Electronic Level Video
Requires the Registered User plan or above. Login!