The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call....
Search Results "Character Height (Visual)"
-
11B-411.2.1.7.3 Assignment by security credential
-
11B-411.2.1.7.3 Assignment by security credential
The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call....
-
6.2 Presentations that Informed the Minimum Height Deliberations
about the minimum transfer surface height recommendation....
-
Appendix to May 23, 2014 Document
Exceptions to the 2010 Standards This table is provided for HUD recipients that elect to use the 2010 Standards under title II of the Americans with Disabilities Act (ADA) as an...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness. ...
- Defining and Delivering Disability-Competent Care - The Lived Experience Of Disability
-
Independent Wheelchair Transfers in the Built Environment: How Transfer Setup Impacts Performance Phase 2: Final Report
Independent Wheelchair Transfers in the Built Environment: How Transfer Setup Impact Performance Phase 2: Final Report REPORT PREPARED FOR: U.S ACCESS BOARD, WASHINGTON,...
-
B. Question 2: Section 904.4.1 and Clear Counter Space
Defendants have satisfied 904.4.1’s length requirement if their transaction counter, as built, equals or exceeds 36 inches in length. An entity does not violate the length...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
- Grainger Tough Guy Stainless Steel Sanitary Napkin Receptacle, 11" Height
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in 308. [ECTCR UFAS 4.34.6.10(2)]
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION: Existing call...
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor.
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor. Front loading machines shall have the bottom of the...
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor.
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in 308.
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION: Existing call...
-
T304.2 Height
Operable parts shall be located 24 inches (610 mm) minimum and 48 inches (1220 mm) maximum above the floor of non-rail vehicles.