5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less...
Search Results "Water Closet Seat"
Commonly Searched Documents
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
-
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations The Committee recommends a minimum two-inch high edge protection on both sides of the...
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side.
-
M302.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
§ 38.75(c)
(c) Characters on signs required by paragraphs (a) or (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and...
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
Adjustable Height Range Considered
seated, and to accommodate patients who need to transfer laterally between the platform and a chair or wheelchair alongside.”...
-
Technical Memorandum TM 2013-14 Dining Surfaces
Calculations At least 5% of the seating and standing spaces at fixed or built-in dining surfaces provided for the consumption of food or drink must comply with 902 based on TAS 226.2....
-
4. Exception from the Requirements of M301 for Certain Examination Chairs that Comply with M302
However, the subcommittee for tables and chairs did explain that while the primary function of examination chairs is to support patients in a seated position, they are also capable of being...
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
Transfer Sides (M301.2.3 and M302.2.3)
The 2004 ADA and ABA Accessibility Guidelines provide a gap of 3 inches between the edge of a shower seat and the shower compartment entry, and the gap does not appear to interfere with...
-
Bradley 812 Grab Bars 1 1/2" Tube Concealed Ends Various Sizes Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick Straight Grab Bar B-6806 Details
Requires the Premium User plan or above. (Login or upgrade your account!)
- Access Board: Alternate Type Roll In Shower Stalls
- Kohler C3® 200 Elongated Bidet Toilet Seat With In-line Heater and Remote Control Video
-
6) Water fountains
6) Water fountains ADAAG: Where there is more than one fountain on a floor, 50% must be accessible to persons using wheelchairs....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base (proposed...
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of...
-
5.8.2.1 Height of Breast Platform at Time of Measurement
5.8.2.1 Height of Breast Platform at Time of Measurement Recommendation The Committee recommends measuring all knee and toe clearances when the top of the breast platform is set...
-
5.8.2.1 Height of Breast Platform At Time of Measurement
5.8.2.1 Height of Breast Platform At Time of Measurement. All knee and toe clearances should be measured when the top of the breast platform is set at 34 inches above the floor.
-
Chapter 2: Methodology
[See subsections ...]