When a ramp is added to provide an accessible entrance, the slope of the ramp should be as shallow as possible but not more than 1:12....
Search Results "Ramp Slope"
Commonly Searched Documents
-
Accessible Entrance
-
LaCantina Aluminum Thermally Controlled Slider System Ramp Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
LaCantina Aluminum Wood Slider System ADA Ramp Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
1. Access Barrier Removal in Existing Pedestrian Facilities
of way; (5) repair of vertical or horizontal displacement or upheaval of the sidewalk or crosswalk surfaces; (6) correction of non-compliant cross-slopes in sidewalks or sections of sidewalks...
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
KIROLA v. THE CITY AND COUNTY OF SAN FRANCISCO
N.D. Cal. UNITED STATES DISTRICT COURT FOR THE NORTHERN DISTRICT OF CALIFORNIA OAKLAND DIVISION Case No: C 07-3685 SBA 11-26-2014 IVANA KIROLA, et al.,...
-
303.3 Beveled
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
11B-406.6 Islands
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides....
-
Handrails Requirement
Requirements for handrails in the proposed rule applied only to those provided along ramps and stairs....
-
R302.5 Grade
Running slope requirements are contained in R304.2.2 for perpendicular curb ramps, in R304.3.2 for parallel curb ramps, in R304.4.1 for blended transitions, and in R407.2 for ramps....
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 11B-303.3 Beveled....
-
Handrails
Handrails are required along both sides of ramps and stairs....
-
10 - foot straightedge method
The same problem exists when measuring slope. There is no way to measure a localized slope that may actually be greater than the overall slope of the straightedge....
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
Figure 18: APS and curb ramps that were not installed as designed. Figure 19: Another view of the same corner....
-
1) Where the Standard specifically refers to 303
such as 403.4 changes in level for walking surfaces: Here it is clear that changes in level that comply with either the ¼" maximum vertical rise, the ½" maximum beveled rise with a slope...
-
LaCantina Multi-slide Aluminum Sliding Door System Ramp Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
LaCantina Aluminum Thermally Controlled Slider System ADA Ramp Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
R105 Definitions (Section-by-Section Analysis)
The proposed guidelines define the following terms: accessible, alteration, blended transition, cross slope, curb line, curb ramp, element, facility, grade break, operable part, pedestrian...
-
STREETS, ROADS AND WALKWAYS {35.150}
STREETS, ROADS AND WALKWAYS {35.150} “If a public entity has responsibility or authority over streets, roads, or walkways, its transition plan shall include a schedule for providing curb ramps...
-
4.5.2 Changes in Level
Changes in level between 1/4 in and 1/2 in (6 mm and 13 mm) shall be beveled with a slope no greater than 1:2 (see Fig. 7(d))....
-
4.5.2 CHANGES IN LEVEL
Changes in level between 1/4 in and 1/2 in (6 mm and 13 mm) shall be beveled with a slope no greater than 1:2 (see Fig. 7(d))....
-
Readily Achievable Barrier Removal
Readily achievable barrier removal may include providing an accessible route from a parking lot to the business’s entrance, installing an entrance ramp, widening a doorway, installing accessible...
-
Construction Specification Institute
Construction Specification Institute While developing suggested tolerances for surface materials, the Construction Specifications Institute developed a suggested method for measuring ramp...
-
11B-106.5 Defined terms
POOL CCR CHARACTERS CHILDREN’S USE CIRCULATION PATH CLEAR CLEAR FLOOR SPACE CLOSED-CIRCUIT TELEPHONE COMMERCIAL FACILITIES COMMON USE COMPLY WITH CROSS SLOPE...