In public housing facilities with individual residential dwelling units, where a bathroom or a kitchen is substantially altered, and at least one other room is altered, the requirements...
Search Results "Kitchen Clearance"
-
11B-233.3.4.2 Alterations to individual residential dwelling units
-
ADAPTABLE
As part of the initial design and construction, for example, structural backing would be provided for the later installation of grab bars, base cabinets under kitchen sinks would be removable...
-
§8.3 Adaptability
Adaptability means the ability of certain elements of a dwelling unit, such as kitchen counters, sinks, and grab bars, to be added to, raised, lowered, or otherwise altered, to accommodate...
-
306.3.5 Width
Knee clearance shall be 30 inches (760 mm) wide minimum. Figure 306.3 Knee Clearance...
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
ACCESS AISLE
[DSA-AC] An accessible space adjacent to or between vehicle spaces that provides clearances in compliance with this code....
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
Dwelling Unit
A single unit which provides a kitchen or food preparation area, in addition to rooms and spaces for living, bathing, sleeping, and the like....
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
- Moen Stainless 30" Grab Bar
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
General: ADA Standard Section 204.1
Section 204.1 of the ADA Standards covers information on scoping requirements for protruding objects in the most current ADA Standards.
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
Sinks [4.24]
common use areas employee break rooms (forward approach access or adaptability preferred) janitor's sinks laboratories for employees only (not students) kitchens...
-
4.34.4 CONSUMER INFORMATION
a dwelling, the following consumer information shall be provided in each adaptable dwelling unit available for occupancy: (1) Notification of the alternate heights available for the kitchen...
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
-
Single-User Toilet Rooms: Split Plumbing
Note that lavatories (and other fixtures) cannot overlap door maneuvering clearances, including latch-side clearances....
-
Benefits
since the UFAS compliant units comply with the technical requirements in the final rule for units with mobility features, except for bedroom lighting controls and water spray units at kitchen...