Section 609.3 covers the current ADA Standards for the grab bar spacing between the wall, objects above, below and at the ends of the grab bar.
Search Results "Building Permit"
-
Spacing: ADA Standard Section 609.3
-
General: ADA Standard Section 902.1
EXCEPTION: Dining surfaces and work surfaces for children’s use shall be permitted to comply with 902.4. Advisory 902.1 General....
-
T-Shaped Space: ADA Standard Section 304.3.2
Section 304.3.2 covers the current ADA Standards for t-shaped turning space.
-
11B-608.7 Thresholds
Exception: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (12.7 mm) high threshold would...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
11B-1005.1 Accessible routes
Exceptions: Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in Section 11B-1003.2.1....
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-605.5.2 Maneuvering clearance
Exception: Where toe clearance complying with Section 11B-605.5.4 is provided, the required maneuvering space in front of the urinal fixture shall be permitted to be reduced to 60 inches...
-
11B-608.7 Thresholds
Exception: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (12.7 mm) high threshold would...
-
11B-1005.1 Accessible routes
Exceptions: Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in Section 11B-1003.2.1....
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-605.5.2 Maneuvering clearance
Exception: Where toe clearance complying with Section 11B-605.5.4 is provided, the required maneuvering space in front of the urinal fixture shall be permitted to be reduced to 60 inches...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
§382.11(a)(3)
qualified individual with a disability from or deny the person the benefit of any air transportation or related services that are available to other persons, except where specifically permitted...
-
11B-107 Special conditions appeals action
Appeals Boards, Local Building Officials or other Authorities Having Jurisdiction have no authority to certify ADA compliance, and consistently state that they do not review for it....
-
11B-107 Special conditions appeals action
Appeals Boards, Local Building Officials or other Authorities Having Jurisdiction have no authority to certify ADA compliance, and consistently state that they do not review for it....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
Boat Slips: ADA Standard Section 1003.2.1
Accessible routes serving boat slips shall be permitted to use the exceptions in 1003.2.1. EXCEPTIONS: 1....
-
11B-1003.2.1 Boat slips
Accessible routes serving boat slips shall be permitted to use the exceptions in Section 11B-1003.2.1....
-
11B-1003.2.1 Boat slips
Accessible routes serving boat slips shall be permitted to use the exceptions in Section 11B-1003.2.1....
-
Physical Accessibility
ensure that students and others with disabilities, including parents, are not denied access to the school’s programs or activities because of inaccessible facilities, including academic buildings...
-
Interacting with People with Significant Allergies, Asthma, Chemical and other Environmental Sensitivities, and Respiratory-related Disabilities
Eliminate use of mechanical dispensers or fragrance delivery systems, which may be attached to walls or ceilings, or may be part of the building's ventilation system....
-
F202.2.4 Public Telephone
Where a public telephone is not provided in an addition but is provided in the existing building or facility to serve the addition, at least one public telephone in the existing building...