The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
Search Results "Bathtub Clearance"
-
604.3.2 Overlap
-
806.2.4 Toilet and Bathing Facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of 603 through 610....
-
806.2.4 Toilet and Bathing Facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of 603 through 610....
-
Single-User Toilet Rooms: Split Plumbing
Note that lavatories (and other fixtures) cannot overlap door maneuvering clearances, including latch-side clearances....
-
TTY Shelf: ADA Standard Section 704.5
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
806.2.4 Toilet and Bathing Facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of 603 through 610....
-
Associated
Associated TAS 604.3.2 allows “associated” grab bars, dispensers, sanitary napkin disposal units, coat hooks, and shelves to overlap the required clearance around an accessible water...
-
1. Abdomen depth (AD)
Univariate analysis The univariate analysis examines AD alone and is appropriate when no other clearance dimension is constrained or bounded (e.g., knee clearance height, foot clearance...
-
Clear Deck Space: ADA Standard Section 1009.4.1
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
11B-1009.4.1 Clear deck space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
11B-1009.4.1 Clear deck space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
General: ADA Standard Section 410.1
Section 410.1 of the ADA Standards covers information in the current ADA Standards for platform lifts.
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
Do drinking fountains pose hazards as protruding objects?
This is not required for wheelchair accessible units with no more than a 27” clearance below (the minimum required for knee clearance and the maximum recognized for cane detection)....
-
Introduction
Introduction This memo provides a revised description and analyses examining knee clearance dimensions in mammography equipment (as requested in your email dated: 4/15/2013)....
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
-
Doors: ADA Standard Section 604.8.2.2
Section 604.8.2.2 covers the current ADA Standards for ambulatory accessible compartment doors.
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....