Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
Search Results "Toilet Room Door"
Commonly Searched Documents
-
11B-404.3.3 Thresholds
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
- Access Board: Doors in a Series
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
-
Technical Memorandum TM 2013-11 Benches
These references are limited to the following: Saunas and Steam Rooms TAS 612.2 Dressing, Fitting, and Locker Rooms TAS 803.4 Holding Cells and Housing Cells TAS...
-
7d.
Is no more than 5 pounds force needed to push or pull open the accessible door?...
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting....
- Access Board: International Symbol of Accessibility (ISA) Scoping Requirements
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
g-iv
Is no more than 5 pounds force needed to push or pull open the door?...
-
7c.
Is there clear maneuvering floor space in front of each accessible door (see Figure 25 in the appendix for measurements) and on the pull side, is there at least 18 inches clear floor space...
-
4.3.11.1(6)
Doors in the smoke barrier shall be tight-fitting smoke- and draft-control assemblies having a fire-protection rating of not less than 20 minutes and shall be self-closing or automatic closing...
- Signaids Women's Washroom Directional Sign
- Signaids Unisex Washroom Directional Sign
- Panda S.66 Solid Wood Folding Door System
- Panda S.51 All Aluminum Folding Door System
-
Directional visual sign vs. room identification tactile sign
The arrow appears to indicate that this specific sign is a directional sign pointing toward the location of an accessible toilet room. ...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
202.2 Additions
202.2 Additions. Each addition to an existing building or facility shall comply with the requirements for new construction. Each addition that affects or could affect the usability...
-
703.5.8 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
703.5.4 Character Proportions
Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I".
-
703.5.4 Character Proportions
Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I".
-
703.5.8 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction. Each addition that affects or could affect the usability of or access to an...