Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm), with bars...
Search Results "Side Grab Bar"
Commonly Searched Documents
-
11B-705.2 Detectable directional texture
-
GUARD [DSA-AC] OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
Maneuvering Clearance: ADA Standard Section 305.7
Section 305.7 covers the current ADA Standards for additional maneuvering clearance needed when the clear floor or ground space is located in an alcove.
-
EXHIBIT F ADA Maintenance Checklist
There also must be sufficient maneuvering room in front of the door on either side. a. Is there an unobstructed clear flat area at the exterior side of the accessible door?...
-
1132A.8 Hand-activated door hardware
Latching and locking doors that are hand-activated and on an accessible route shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars or other...
-
1132A.8 Hand-activated door hardware
Latching and locking doors that are hand-activated and on an accessible route shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars or other...
- UMEA Waste Receptacle
- EduCAPTION
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
Can maneuvering for a forward approach be provided when there is space at least 60” deep in front of a door?
Space at least 60” deep in front of a door that is unobstructed on approach sides will provide sufficient depth for a forward approach if appropriate strike-side clearance is provided; but...
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
ADDENDUM TO PHASE I FINAL REPORT: Points of Clarification
their mobility devices in the way that they would normally do to perform an independent transfer because they were hindered by the foot constraints that were fixed on the floor along the sides...
-
Elevator Doors: ADA Standard Section 409.3
Section 409.3 covers the current ADA Standards for the doors of private residence elevators.
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
1011.2.1 Size and Location
right side or left side....
-
1. Making Facilities Accessible and Usable
For example: A restroom may be modified to meet standard accessibility requirements (including wider door and stalls, and grab bars in specified locations) but it may be necessary to install...
-
F234 Residential Facilities
For example, grab bars do not have to be installed during the construction of residential dwelling units if the proper reinforcement is provided to facilitate their later installation as...
-
M305.3 Standing Supports (Section-by-Section Analysis)
In the MDE NPRM preamble, the Access Board noted that it was considering adopting the cross section dimensions for grab bars from the 2004 ADA and ABA Accessibility Guidelines and applying...
-
2010 ADA Standards
For example, if this document requires “1½ inches,” avoid specifying “1½ inches plus or minus X inches. ”Where the requirement states a specified range, such as in Section 609.4 where grab...
-
104.1.1 Construction and Manufacturing Tolerances
Where the requirement states a specified range, such as in Section 609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate...
-
104.1.1 Construction and Manufacturing Tolerances
Where the requirement states a specified range, such as in 609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate tolerance...
-
1 - Design and drawing
Tolerances do not apply where a requirement states a range; for example, that grab bars must be installed between 33 inches and 36 inches above the finished floor....
-
Size: ADA Standard Section 604.3.1
Section 604.3.1 covers the current ADA Standards for the size of the water closet clearance.