In order to image as much of the breast as possible, patients cannot be seated in the “natural” sitting position....
Search Results "Elongated Water Closet Seat"
-
5.8.2.4 Unobstructed Floor Space Recommendation
-
Clear Space Evaluation
Increasing the width of the clear floor space an additional 12 inches to 72 inches would accommodate 75-77% of users who would be expected to transfer higher or lower than their seat to...
-
5.8.2.5 Toe Height Recommendation
However, it is important to provide extra toe space for patients who are seated close to the ground but have their footrests positioned at more of an angle....
-
(1) Adjustability: Minimum High Transfer Height
Seat heights for males were typically higher than for females....
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
Elongated surface openings must be perpendicular to the dominant direction of travel, but what if there is no dominant direction of travel?
Where space allows accessible routes to completely bypass the area with openings, elongated openings can be oriented in either direction....
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
and Toe Clearance Recommendations under Breast Platform Recommendations Description: The knee and toe clearance under the breast platform applies to mammography equipment for patients seated...
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 148 Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 148 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 148 Front Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Clearances Around Gripping Surfaces
gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum. EXCEPTION: Wheelchair spaces located on raised platforms shall be permitted to be 32 inches (815 mm) wide minimum to a...
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.2.4 Equipment Clearances
Where wheelchair spaces are entered from the rear and includes space beneath components, wheelchair spaces shall include knee and toe clearances complying with M303.2.4.1 for breast...
-
M303.3.2 Beveled (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes greater than ¼ inch but not greater than ½ inch would be required...
-
M303.3.1 Vertical (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes of up to ¼ inch high are permitted to be vertical. This provision...
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
In the proposed rule, obstructions were not permitted within the knee and toe clearance space. This is consistent with the requirement in the existing accessibility guidelines and...
-
M303.1 General (Section-by-Section Analysis)
This is an introductory section.
-
Base Support [No specific provision—affects M303.2.4]
Base Support [No specific provision—affects M303.2.4] Recommendation: The final proposal on the base support is for 1½ inch high maximum base support with additional sloping...
-
Key Features of Accessible Stadiums
[See subsections ...]
-
CHAPTER 6: WHEELCHAIR SPACES AND SECUREMENT SYSTEMS
[See subsections ...]
-
M303.2.4 Knee and Toe Clearance
Wheelchair spaces shall include knee and toe clearance complying with M303.2.4. The depth of the wheelchair space shall include knee and toe clearance of 17 inches (430 mm) minimum...