Currently, the only equipment existing with a 30-inch transfer surface width is bariatric equipment. At the Committee’s December 2012 meeting, Dr....
Search Results "Wheelchair Space (Medical Diagnostic Equipment)"
-
5.2.1.1 Transfer Surface Width Recommendations for M301
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
100% Healed Policies
100% Healed Policies An employer will violate the ADA if it requires an employee with a disability to have no medical restrictions -- that is, be "100%" healed or recovered -- if the...
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
-
Knee Clearance: Clearance as Measured from Distal Knee Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the distal knee point touching an obstruction....
-
Incidental Rooms and Spaces
These can include work areas such as equipment control rooms, projection booths, radio and news booths, press boxes, and other occupiable spaces of incidental use where the maximum occupancy...
-
Knee Clearance: Clearance as Measured from Anterior-Most Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the forward-most point touching the wall....
-
Knee Clearance: Clearance as Measured from Dorsal Foot Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the dorsal foot point touching an obstruction....
-
Section 1630.13(b) Examination or Inquiry of Employees
Section 1630.13(b) Examination or Inquiry of Employees The purpose of this provision is to prevent the administration to employees of medical tests or inquiries that do not serve a...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided....
-
R203 Machinery Spaces
R203 Machinery Spaces. Vaults, tunnels, and other spaces used by service personnel only for maintenance, repair, or monitoring are not required to comply with this document....
- Taking your first Spin on the Johnny G KRANKcycle® by Matrix
-
E202.4 ICT Functions Located in Maintenance or Monitoring Spaces
Where status indicators and operable parts for ICT functions are located in spaces that are frequented only by service personnel for maintenance, repair, or occasional monitoring of equipment...
-
309.2 Clear Floor Space
309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided....
-
Door Swing: ADA Standard Section 304.4
Section 304.4 covers the current ADA Standards for doors swinging into turning spaces.
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
C201.1 Scope
Manufacturers of telecommunications equipment shall comply with the requirements in the 255 Guidelines applicable to such equipment when newly released, upgraded, or substantially changed...
-
11B-1009.3 Sloped entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
11B-1009.3 Sloped entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
11B-1009.3 Sloped entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
Clear Deck Space
Clear Deck Space The base of the transfer platform must have a clear deck space adjacent to it that is 60 by 60 inches minimum, with a slope not steeper than 1:48 so a person using a...
-
Regulatory Flexibility Act
In particular, the certification noted that manufacturers of telecommunications equipment and customer premises equipment are required to comply with section 255 of the Telecommunications...