Each topic is divided into the following sections: Overview—provides general information and context about emergency planning programs, services, resources that were discussed at the...
Search Results "Special Service System"
- Emergency Planning for People with Access and Functional Needs
-
Sales and Service Counters, Teller Windows, Information Counters [7.2]
Sales and Service Counters, Teller Windows, Information Counters [7.2] ADAAG generally specifies accessible counter heights up to 34 inches [4.32] but allows a height up to 36 inches...
-
Role of HHS and DOJ
Federal financial assistance from HHS, including child welfare agencies and state courts, comply with their legal obligation under Section 504 to provide equal access to child welfare services...
-
§382.85 What seating accommodations must carriers make to passengers in circumstances not covered by §382.81 (a) through (d)?
in the four categories listed in §382.81 (a) through (d) of this part and as needing a seat assignment accommodation in order to readily access and use the carrier's air transportation services...
-
706.6 Peak Clipping Level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech. [ECTCR UFAS 4.33.7]
-
708.3 Handsets
Handset cords, if provided, shall be 29 inches (735 mm) long minimum.
-
§382.83 Through what mechanisms do carriers make seating accommodations?
[See subsections ...]
-
11B-706.6 Peak clipping level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
382.83 Through what mechanisms do carriers make seating accommodations?
382.83 Through what mechanisms do carriers make seating accommodations? ETA Editor's Note This section has no content in the original document.
-
11B-708.3 Handsets
Handset cords, if provided, shall be 29 inches (737 mm) long minimum.
-
708.3 Handsets
Handset cords, if provided, shall be 29 inches (735 mm) long minimum.
-
706.6 Peak Clipping Level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
Requirements to Remember for: Light Rail Projects
[See subsections ...]
-
706.6 Peak Clipping Level
706.6 Peak Clipping Level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
708.3 Handsets
708.3 Handsets. Handset cords, if provided, shall be 29 inches (735 mm) long minimum.
-
4.28.3(3)
(3) The maximum pulse duration shall be two-tenths of one second (0.2 sec) with a maximum duty cycle of 40 percent. The pulse duration is defined as the time interval between initial...
-
4.3.11.4* Two-way Communication
A method of two-way communication, with both visible and audible signals, shall be provided between each area of rescue assistance and the primary entry. The fire department or...
-
A4.28 Alarms
[See subsections ...]
-
Location and Spacing
Location and Spacing Rooms with an area than can be circumscribed by a circle 50 feet in radius can be covered by a single centrally located strobe of 75 cd. For very small rooms,...
-
A4.28.2 Audible Alarms
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
4.28.3(5)
(5) The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz.
-
Mounting Height
Mounting Height ADAAG specifies a signal height 80 inches above the highest floor level within the space or 6 inches below the ceiling, whichever is lower. (This can be measured...
-
4.28 Alarms
[See subsections ...]
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound...