Rail platforms shall not exceed a slope of 1:48 in all directions. Exception: Where platforms serve vehicles operating on existing track or track laid in existing roadway, the...
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
11B-810.5.1 Slope
-
11B-810.5.1 Slope
Rail platforms shall not exceed a slope of 1:48 in all directions. Exception: Where platforms serve vehicles operating on existing track or track laid in existing roadway, the...
-
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301)
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301) The Committee recommends a minimum transfer surface size of 28 inches wide by 17 inches deep for stretchers located...
-
226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902....
-
4.7.6 Water Hydrant Clear Floor or Ground Space
Clear floor or ground space around a water hydrant shall be 48 inches (1220 mm) by 72 inches (1830 mm) with the long side of the space adjoining an outdoor recreation access route, trail...
-
1013.2 Where required
to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge of the open side....
-
1015.2 Where required
vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge of the open side....
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
Exercise Machines and Equipment
Section 236 of the 2010 Standards requires at least one of each type of exercise machine to meet clear floor space requirements of section 1004.1....
-
11B-604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height...
-
4.7.7 Water Spouts
Water spouts shall be located in the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the clear floor or...
- 305.3 Trash Can Clear Floor Space
- 604.3.1 Water Closet Clear Floor Space
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Lavatories can be located within the clear floor space (as shown in ADAAG Figure 35)....
- Electrolux Icon 36" Freestanding Full-Gas Range
-
1015.6 Slope
The slope of the surface of clear ground spaces and turning spaces shall not be steeper than 1:48 in any direction....
-
1015.6 Slope
The slope of the surface of clear ground spaces and turning spaces shall not be steeper than 1:48 in any direction....
-
Slope [4.3.7]
Requirements in 4.3, while based on the expectation of level floors, apply equally to exterior sites....
-
Changes in Level - Accessible Route Tool
Changes in Level - Accessible Route Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring changes in level along an accessible...
-
Bathroom Accommodating Reduced Ambulatory Mobility
Ceiling lift between the bathtub and toilet (this is actually fun to use) – reinforcement less than $50 Chromatherapy bathtub for relaxation FSC certified maple floor...
-
1013.3 Height
From the adjacent walking surfaces; 2. On stairs, from the line connecting the leading edges of the tread nosings; and 3. On ramps, from the ramp surface at the guard....