between the area for assisted rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or unprotected opening shall be constructed...
Search Results "Completion of Construction"
-
1007.8 Exterior area for assisted rescue
-
Obstacles [1018.5]
When beach access routes are constructed of concrete, asphalt, or boards, obstacles cannot exceed one-half inch in height at their highest point....
-
6. DOCUMENTATION
DoD Component Heads shall ensure that each contract, grant, or loan for the design, construction, or alteration of a facility subject to these DoD Standards and each lease for a facility...
-
1003.2.13.7 Exterior area for assisted rescue
between the area for assisted rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or unprotected opening shall be constructed...
-
Applying the Forest Service Outdoor Recreation Accessibility Guidelines
Section 1.0 "Application" states that newly constructed and altered camping facilities, picnic areas, constructed features, beach access routes, and outdoor recreation access routes under...
-
4.1.2(6)
EXCEPTION: Portable toilet units at construction sites used exclusively by construction personnel are not required to comply with 4.1.2(6)....
-
4.1.6(4)(a)
Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises as shown in Table 2 if space limitations prohibit the use of a 1...
-
How the ADA Standards are Enforced
They constitute design and construction requirements issued under a civil rights law....
-
Wiring for Visible Alarms [§215.3]
Wiring for Visible Alarms [§215.3] All employee work areas served by audible fire alarms, regardless of size, must be designed to support later installation of visible alarms after construction...
-
Alterations: ADA Standard Section 223.1.1
Section 223.1.1 ADA Standards for alterations to medical care and long-term care facilities.
-
Alterations: ADA Standard Section 224.1.1
Section 224.1.1 covers scoping requirements in the current ADA Standards for alterations to transient lodging guest rooms.
-
Applicable standards. (Section-by-Section Analysis)
Section 36.406(a) adopts the 2004 ADAAG as part of the 2010 Standards and establishes the compliance date and triggering events for the application of those standards to both new construction...
-
Trailhead Signs
Therefore, when new information signs are provided at trailheads for newly constructed or altered trails, include at minimum the following information: Trail name Length...
-
III-4.4400 Continuing obligation
The obligation to remove barriers will never exceed the level of access required under the alterations standard (or the new construction standard if ADAAG does not provide specific standards...
-
VALUATION THRESHOLD
The baseline valuation threshold of $50,000 is based on the January 1981, “ENR US20 Cities” Average Construction Cost Index (CCI) of 3372.02 as published in Engineering News Record, McGraw...
-
II-3.6100 General
When many individuals with mental disabilities apply for benefits, they are unable to complete the application process successfully....
-
11B-810.1.1 Vehicle boarding
Stations shall not be designed or constructed so as to require persons with disabilities to board or alight from a vehicle at a location other than one used by the general public....
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
-
32. Paragraph Headings
Paragraph Headings The headings, or lack thereof, preceding each of the paragraphs in this Settlement Agreement are for convenience only, and shall not be considered in the construction...
-
§ 35.150(b)(5)(iii)
(iii) Where an existing sauna or steam room was designed and constructed to seat only two people, it shall be exempt from the provisions of § 241 of the proposed standards....
-
§35.151(e)(2)
(2) Newly constructed or altered street level pedestrian walkways must contain curb ramps or other sloped areas at intersections to streets, roads, or highways....
-
§ 36.406(c)(3) Facilities with residential units and transient lodging units
Residential dwelling units that are designed and constructed for residential use exclusively are not subject to the transient lodging standards....
-
4.3.11.1(3)
(3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire-resistive construction and for openings) located immediately adjacent to an exit enclosure...
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....