Captions (Section-by-Section Analysis) This section proposes that, where audio-visual players and displays process video with synchronized audio, they must decode closed caption data and support...
Search Results "Transfer Support"
-
411.1.1 Decoding of Closed Captions (Section-by-Section Analysis)
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting...
-
§100.500(b)(2)
(2) A legally sufficient justification must be supported by evidence and may not be hypothetical or speculative....
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting...
-
4. Grab Bars
accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for stabilization and assistance during transfer...
-
G. Compartment Size
the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use wheelchairs to approach the toilet from a variety of transfer...
- Zurn Insulation Combination Kit: One Trap Protector, Two Stop Supply Protectors and One Offset Drain Protector
-
Ability Self-Assessment
Be prepared to use alternative ways to negotiate your environment (i.e. sighted guides, members of your personal support network who can offer emotional support)....
-
M302.1 General
Diagnostic equipment that supports patients in a seated position shall comply with M302. ...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting...
-
§ 1194.2(a)(2)
(2) When procuring a product, if an agency determines that compliance with any provision of this part imposes an undue burden, the documentation by the agency supporting the procurement...
-
4.26.3(3)
Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting device or the supporting...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting...
- Sorenson Video Relay Service ntouch® PC
-
§104.5(b)(1)
financial assistance extended in the form of real property or to provide real property or structures on the property, the assurance will obligate the recipient or, in the case of a subsequent transfer...
-
§8.50(b)(1)
financial assistance extended in the form of real property or to provide real property or structures on the property, the assurance will obligate the recipient or, in the case of a subsequent transfer...
-
5. Grab Bars
accessible guestroom bathroom have a horizontal grab bar along the wall behind the toilet that is at least 36" long and mounted 33"-36" above the floor for stabilization and assistance during transfer...
-
Mechanical Access Parking Garages
However, such facilities must provide at least one accessible passenger loading zone at vehicle drop-off and pick-up areas so that people with disabilities can transfer from vehicles (§209.5...
-
M304.2 Standing Surface (Section-by-Section Analysis)
The requirement for slip resistant and standing supports has been moved under this new requirement applying to standing surfaces....
-
iii. Radiological Diagnostic equipment
Some individuals with disabilities had difficulty transferring from wheelchairs onto scanning tables and were denied staff assistance or not provided access to medical equipment and furniture...
-
Recessed Lavatories
Recessed Lavatories Recessing lavatories can provide space for side transfers while allowing a narrower room width....
-
410.6 Real-Time Text Functionality (Section-by-Section Analysis)
Proposed 410.6 would require that, where ICT supports real-time voice communication, it must also support RTT functionality....
-
240.2.1 Ground Level Play Components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....