Positions CHAPTER 3: BUILDING BLOCKS 301 General 302 Floor or Ground Surfaces 303 Changes in Level 304 Turning Space 305 Clear Floor or Ground Space 306 Knee and Toe...
Search Results "Toe Clearance"
-
TABLE OF CONTENTS
-
11B-604.5.1 Side wall
2013 CEC) requires a nurse call device at the side wall of a water closet that must be coordinated carefully with the side grab bar at an accessible water closet to ensure that accessible clearances...
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. Figure 505.4 Handrail Height...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
11B-505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. FIGURE 11B-505.4 HANDRAIL HEIGHT...
-
A4.31.9 Text Telephones
text telephone which is not a single integrated text telephone pay phone unit will require a shelf large enough (10 in (255mm) wide by 10 in (255 mm) deep with a 6 in (150 mm) vertical clearance...
-
Additional Technical Criteria Considered for Handrails on Ramps
These technical criteria are available at http://www.access-board.gov/ada-aba/final.cfm#a505 and address continuity, height, clearance, gripping surface, cross section, surfaces, fittings...
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment....
-
RECOMMENDATIONS
32.7 m Vertical alignment-crest 49.8 m Recumbent bicyclists 46.7 m Refuge islands 2.5 m Bicyclists with trailers 3.0 m Signal clearance...
- PEMKO 6" Heavy Duty Threshold No. 1716
- Rockwood Manufacturing Company 215L Tapered Door Pull 28"
- Rockwood Manufacturing Company 215 Tapered Door Pull 16"
- Inclusion Solutions Model 2000 Voting Booth with Light (Hard Curtain)
- Inclusion Solutions Model 2000 Voting Booth (Hard Curtain)
- Inclusion Solutions Poll Star Voting Booth
-
Typical examples of reasonable accommodations are:
If the employer has an employee parking lot, reserving a parking space close to the entrance for an employee who has difficulty walking because of the loss of a leg, foot, or toe....
-
11B-605.5.3 Doors
Urinal compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-605.5.3 Doors
Urinal compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
Mammography Equipment
2.It is best to position equipment to allow both front and side approaches; for some patients a side or angled approach may be better for positioning at the camera unit and plate. 3.Clearance...
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
Accessible Restrooms, Fitting Rooms, and Elevators
Remove trash receptacles and cigarette urns from under elevator hall call buttons and beside doors to ensure access to controls and sufficient maneuvering clearance....