Architectural Barriers Act The Architectural Barriers Act (ABA) requires that buildings and facilities that are designed, constructed, or altered with Federal funds, or leased by...
Search Results "Mobile Health Screening Unit"
-
Architectural Barriers Act
-
Requirement 7 -- Usable Kitchens and Bathrooms
[See subsections ...]
-
26.1 Q. Is a parallel approach required at the shower, as shown in Figure 7(d) of the Guidelines?
A. Yes. For a 36 x 36 shower, as shown in Figure 7(d), a person in a wheelchair would typically add a wall hung seat. Thus the parallel approach as shown in Figure 7(d) is essential...
-
1012.5 Slope
This section requires the slope of the surface of parking spaces and pull-up spaces to not be steeper than 1:48 in any direction. Where the surface is other than asphalt, concrete,...
-
§100.205(c)(3)(iv)
(iv) Usable kitchens and bathrooms such that an individual in a wheelchair can maneuver about the space.
-
(3) Usable bathrooms
., a room with only a toilet and a sink) when the powder room is the only toilet facility on the accessible level of a covered multistory dwelling unit....
-
Features of Accessible Exam Tables
Features of Accessible Exam Tables 1. Removable/adjustable support rails with continuous gripping surfaces 2. 30” X 48” minimum clear floor space adjacent to exam table and...
-
11B-809.10.1 General
All toilet and bathing rooms on an accessible route within residential dwelling units with adaptable features shall comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.6.4, 11B-809.10.7.3...
-
809.5.6 Site, Building, or Floor Entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply...
-
11B-233.3.4 Alterations
dwelling units required by Sections 11B-233.3.1.1 and 11B-233.3.1.3, as applicable, is satisfied....
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
Water Closet Clear Floor Space in Toilet Compartments
However, the Board has revised the specified depth in residential dwelling units where lavatories are permitted to overlap the space aside water closets....
-
F208.3.2 Residential Facilities
In residential facilities containing residential dwelling units required to provide mobility features complying with 809.2 through 809.4, parking spaces provided in accordance with F208.2.3.1...
-
208.3.2 Residential Facilities
In residential facilities containing residential dwelling units required to provide mobility features complying with 809.2 through 809.4, parking spaces provided in accordance with 208.2.3.1...
-
208.3.2 Residential Facilities
In residential facilities containing residential dwelling units required to provide mobility features complying with 809.2 through 809.4, parking spaces provided in accordance with 208.2.3.1...
-
11B-220.2 Point-of-sale devices
In addition, point-of-sale systems that include a video touch screen or any other non-tactile keypad shall comply with either Section 11B-707.9.1.1 _|Tactilely Discernible Numerical Keypad...
-
Section 3. Fair Housing Act Design and Construction Requirements
ETA Editor's Note Section 3 of the original document reprints the text of 24 CFR §100.205, which implements the Fair Housing Act's accessibility requirements. However, the...
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
-
Controls for Ranges and Cooktops
The commenter stated that standards that specify certain design features for appliances in individual dwelling units exceed the scope of the Department's statutory authority....
-
F206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
2. b. WIDE AND EASY TO OPEN EXTERIOR AND INTERIOR DOORS
[See subsections ...]
-
2. a. iii. Clear (Path-of-Travel) Floor Space
Access also includes how people will move into and around lobby and office reception areas, and determine the unobstructed floor or ground space to accommodate a wheelchair user....