The requirement for a minimum 48 inch width between handrails is specific to stairs adjacent to areas of rescue assistance and does not apply generally to stairs covered by 4.9....
Search Results "Handrail Clearance"
Commonly Searched Documents
-
Egress Stairs
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
1003.2.13.2 Enclosed stairways
An enclosed stairway, to be considered part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area...
-
1005.3 Edge Protection
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
306.3.5 Width
Knee clearance shall be 30 inches (760 mm) wide minimum. Figure 306.3 Knee Clearance...
-
1007.8.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
§ 38.155(b)
(b) Where provided within passenger compartments, handrails or stanchions shall be sufficient to permit safe on-board circulation, seating and standing assistance, and alighting by persons...
- Rebuilding Together Portland - Portland, OR
-
General: ADA Standard Section 204.1
Section 204.1 of the ADA Standards covers information on scoping requirements for protruding objects in the most current ADA Standards.
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-405.9 Edge protection
Exceptions: Edge protection shall not be required on ramps that are not required to have handrails and have sides complying with Section 11B-406.2.2....
-
TTY Shelf: ADA Standard Section 704.5
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
Single-User Toilet Rooms: Split Plumbing
Note that lavatories (and other fixtures) cannot overlap door maneuvering clearances, including latch-side clearances....
-
1991 Standards v. 2010 Standards
The 1991 Standards, at sections 4.8.5, 4.9.4, and 4.26, and the 2010 Standards, at section 505, contain technical requirements for handrails....
-
1607.8 Loads on handrails, guards, grab bars shower seats, dressing room bench seats and seats
[See subsections ...]
-
M303.3.3 Ramped (Section-by-Section Analysis)
wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with technical requirements for running slope, cross slope, clear width, edge protection, and handrails...
-
Access to Performing Areas [4.33.5]
While handrails are not required on ramps adjacent to assembly seating, locating aisles (including those that are stepped) along walls will permit handrails on one side for the benefit of...