CHAPTER 6: WHEELCHAIR SPACES AND SECUREMENT SYSTEMS
-
M303.2.4 Knee and Toe Clearance
Wheelchair spaces shall include knee and toe clearance complying with M303.2.4. The depth of the wheelchair space shall include knee and toe clearance of 17 inches (430 mm) minimum...
-
M303.2.4.1 Toe Clearance
Toe clearance shall be provided at a height of 9 inches (230 mm) above the floor to a depth of 6 inches (150 mm) maximum.
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.2.4.2 Knee Clearance
Knee clearance shall be provided at a depth of 11 inches (280 mm) minimum and 25 inches (635 mm) maximum at 9 inches (230 mm) above the floor and at a depth of 8 inches (205 mm)...
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
11B-405.8 Handrails
Ramp runs shall have handrails complying with Section 11B-505. [2010 ADAS] 405.8 Handrails. Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails complying...
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit? Is there space in the exam room for an individual using a wheelchair or other mobility aid to move and...
-
11B-405.8 Handrails
Ramp runs shall have handrails complying with Section 11B-505. [2010 ADAS] 405.8 Handrails. Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails complying...
-
11B-405.8 Handrails
Ramp runs shall have handrails complying with Section 11B-505. [2010 ADA Standards] 405.8 Handrails. Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails...
-
Figure M5: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and 304 Diagnostic Equipment for Use by a Patient in a Standing Position (Mammography Machine Example)
The mammography machine is usable by both people who are seated in wheelchairs and those who stand and must meet the requirements of both Sections M303 and M304. (M101.2)...
-
Fixed tactile maps
Fixed tactile maps Fixed tactile maps have the advantage that they can be affixed in the environment where they can be found by the person with vision loss and positioned in the correct...
-
T202 Accessible Means of Boarding and Alighting
All buses, OTRBs, and vans covered under the 2016 Non-Rail Vehicle Guidelines must provide at least one means of accessible boarding and alighting that serves all designated stops on...
-
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
B. M301 Diagnostic Equipment Used by Patients in a Supine, Prone, or Side-lying Position and M302 Diagnostic Equipment Used by Patients in a Seated Position
final rule M301 and M302 provide the technical requirements for diagnostic equipment used in the supine, prone, or side-lying position, and diagnostic equipment used by patients in the seated...
-
Plan 5B: 13-Foot Wide Accessible Guest Room
The following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Transfer shower (section 603.2); • Shower seat (section 610.3...
-
General Requirements of Part 382
Carriers shall permit a service animal to accompany a qualified individual with a disability in any seat in which the person sits, unless the animal obstructs an aisle or other area that...
-
4.1.4(4) ASSEMBLY
Assembly occupancy includes, among others, the use of a building or structure, or a portion thereof, for the gathering together of persons for purposes such as civic, social or religious...
- American Standard Yorkville 1.6 gpf Right Height Elongated Pressure Assisted Toilet
- American Standard Cadet 1.6 gpf Right Height Elongated Pressure Assisted Toilet
-
Whitehall Mfg. WH2125A On-Floor ADA Compliant Bariatric Stainless Steel Toilet
Requires the Premium User plan or above. (Login or upgrade your account!)