For stairs 60 in. (1520 mm) or less in width, measure along a line approximately 18 in. (460 mm) from the wall or outside edge of the stair....
Search Results "Head End Wall"
Commonly Searched Documents
-
1.1.17 Stairs
- Pilot Rock AT Series Traditional A-Frame Picnic Table With Steel Braces - Using Recycled Plastic
- Landscape Forms Inc. Parallel 42 Bench Collection
-
Alteration
restoration, resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls...
-
11B-804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
404.2.4.3 Recessed Doors and Gates
A door can be recessed due to wall thickness or because of the placement of casework and other fixed elements adjacent to the doorway....
-
704.8.2 First story
In occupancies other than Group H, unlimited unprotected openings are permitted in the first story of exterior walls facing a street that have a fire separation distance of greater than...
-
201.3 Temporary and Permanent Structures
facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall...
-
604.8.1.6 Lavatory
new construction, the wheelchair accessible toilet compartment shall contain an accessible lavatory within it, which must be at least 19 inches wide by 17 inches deep, nominal size, and wall-mounted...
-
1134A.6, Item 1.2
water closet may project a maximum of 12 inches (305 mm) into the opening provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower wall...
-
Alteration
renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
Extensions
Extensions must be rounded or returned to the walls, floors, or posts....
-
Alteration of a recreation site, building, or facility
restoration, change in surface of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
Time Management
to make an alarm after assigning ample time to complete a task Provide a checklist of assignments Supply an electronic or handheld organizer and train how to use effectively Use a wall...
-
4.34.6.10* KITCHEN STORAGE
(2) Door pulls or handles for wall cabinets shall be mounted as close to the bottom of cabinet doors as possible....
-
Can handrails or other elements overlap door maneuvering clearances?
However, door maneuvering clearances can be offset up to 8” from the face of the door or gate to accommodate wall thickness, casework, shelves, or other elements adjacent to doorways, including...
-
Can handrails overlap door maneuvering clearances?
However, door maneuvering clearances can be offset up to 8” from the face of the door or gate to accommodate wall thickness, casework, shelves, or other elements adjacent to doorways, including...
-
11B-804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
11B-201.3 Temporary and permanent structures
facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall...
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
11B-804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware. ◼...
-
Boat Slip Clearance: ADA Standard Section 1003.3.1
All other accessible slips are allowed to have the required pier clearance at the head of the slip....