The single bench has a frame at each end, while the double bench has a frame at each end and one in the center....
Search Results "Head End Wall"
- Landscape Forms Inc. FGP Bench Collection
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture....
-
Standard Units
Recessing units in alcoves, wing walls, or other means of providing a detectable leading edge at or below 27 inches are acceptable....
-
4.21.3 SEAT
The seat shall be on the wall opposite the controls. The structural strength of seats and their attachments shall comply with 4.26.3....
-
Maneuvering Clearances [§404.2.4]
Such doors are usually wider to accommodate beds and gurneys, and they are often located close to adjacent interior walls to facilitate circulation and to enhance privacy. ...
-
What types of electrical or communication receptacles are exempt because they serve a “dedicated use”?
Electrical receptacles serving a dedicated use include those installed for appliances, including refrigerators, ranges, and dishwashers, and wall clocks....
-
M301.3.2 Leg Supports (Section-by-Section Analysis)
distinction between stirrups which often only support the feet and leg supports which would support the legs when the patient’s feet are in the stirrups and to provide consistency with the headings...
-
1115B.4.5, Item 5
A shower spray unit with a hose at least 60 inches (1524 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
Housekeeping
Ensure the shower head is placed at its lowest level on the rod. Ensure toiletry items are placed within reach limits for those with limited reach range....
-
Section 2. Definitions
Comments on specific definitions are discussed either below or in that portion of the preamble under the particular section heading of the Guidelines in which these terms appear....
-
B. NOTIFICATION
of this Consent Decree, the County will adopt and follow the attached Notice under the Americans with Disabilities Act, Attachment A (“Notice”); distribute the Notice to all its agency heads...
-
1115B.8.4
Toilet tissue dispensers shall be located on the wall within 12 inches (305 mm) of the front edge of the toilet seat, mounted below the grab bar, at a minimum height of 19 inches (485 mm...
-
606.2 Clear Floor Space (Exception 3)
cabinetry to be installed under lavatories and sinks in residential dwelling units required to provide mobility features provided that the finish floor extends under the cabinetry and the walls...
-
New construction and alteration requirements
For example, installing a new display counter, moving walls in a sales area, replacing fixtures, carpet or flooring, and replacing an entry door....
-
Master Bedroom
Carpet also prevents slip and fall and cushions the blow if a fall occurs Quilted fabric wall and carpet to absorb ambient noise Duvet covers (make the bed with one hand...
-
ALTERATION
restoration, resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls...
- Pilot Rock WXT and WXTH Picnic Table Using Aluminum
- Pilot Rock WUT and WUTH Picnic Table - Using Aluminum
-
1115B.3.2, Item 3
The centerline of the water closet fixture shall be18 inches (457 mm) from the side wall or partition....
-
505.10.2 Top Extension at Stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
7(2)(a)
(a) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the bathroom...
-
Extensions
Handrails that are not continuous must have horizontal extensions at both the top and bottom of the ramp at least 12 inches long that are rounded or returned smoothly to walls, posts, or...
- Pilot Rock APTX Snow Load/Extreme Load Full Size Pedestal Utility Table