The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
Search Results "Clear Floor Space"
-
11B-809.7.1 Width
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
-
Accessibility
Accessibility: When ceramic tile is used as the flooring surface, design professionals should consider the following, based on ANSI A108.01 and A108.02, where accessibility is a primary...
-
11B-233.3.1.2.6.5 Additional requirements.
1. Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
-
4.3.5.3 180-degree turn around an obstacle
In effect, this condition is a space bounded by three sides and requires a lot more space because WhMD users cannot cut the corner like they can with a wider aisle width (Figure 4‒6)....
-
R203 Machinery Spaces (Section-by-Section Analysis)
R203 Machinery Spaces (Section-by-Section Analysis) Vaults, tunnels, and other spaces used by service personnel only are not required to comply with the proposed guidelines....
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs,...
-
R302.3 Continuous Width
Clear width requirements are contained in R304.5.1 for curb ramps and blended transitions, and in R407.4 for ramps....
-
Extended Floor or Ground Surface: ADA Standard Section 405.9.1
Section 405.9.1 covers the current ADA Standards for extended floor or ground surface of the ramp run or landing.
-
809.2.2 Turning Space
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
11B-807.2.1 Turning space
Turning space complying with Section 11B-304 shall be provided within the cell....
-
11B-807.2.1 Turning space
Turning space complying with Section 11B-304 shall be provided within the cell....
-
11B-806.2.6 Turning space
Turning space complying with Section 11B-304 shall be provided within the guest room....
-
11B-806.2.6 Turning space
Turning space complying with Section 11B-304 shall be provided within the guest room....
-
809.2.2 Turning Space
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
809.2.2 Turning Space
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
802.1 Wheelchair Spaces
Wheelchair spaces shall comply with 802.1....
-
106.5.77 Wheelchair Space
Space for a single wheelchair and its occupant....
-
802.1 Wheelchair Spaces
Wheelchair spaces shall comply with 802.1....
-
4.10.9 Floor Plan of Elevator Cars
The floor area of elevator cars shall provide space for wheelchair users to enter the car, maneuver within reach of controls, and exit from the car....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
The floor area of elevator cars shall provide space for wheelchair users to enter the car, maneuver within reach of controls, and exit from the car....
- Moen M–DURA Chrome One-Handle Laboratory Faucet 8106