Search Results "BAR: Beach Access Route"
Commonly Searched Documents
- HEWI Stationary Support Rail Mono WARM TOUCH
-
Passing Spaces [1016.4]
When the intersection of two ORARs serves as a passing space, the vertical alignment of the routes at the intersection that form the T-shaped space must be nominally planar (i.e., as flat...
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
- HEWI Hinged Support Rail Mono WARM TOUCH
-
Performance Areas
Performance Areas An accessible route must connect stages and other performance areas directly to seating areas where they are directly connected by a circulation path as well as to...
-
4.22.4 Water Closets
where 6 or more stalls are provided, in addition to the stall complying with 4.17.3, at least one stall 36 in (915 mm) wide with an outward swinging, self-closing door and parallel grab bars...
- HEWI Stationary Support Rail Duo WARM TOUCH
- HEWI Hinged Support Rail Duo WARM TOUCH
-
11B-206.4.4.1 Location
In transportation facilities, where different entrances serve different transportation fixed routes or groups of fixed routes, entrances serving each fixed route or group of fixed routes...
-
F225.2.2 Self-Service Shelving
Self-service shelves shall be located on an accessible route complying with 402. Self-service shelving shall not be required to comply with 308....
-
R302.3 Continuous Width
Except as provided in R302.3.1 and R302.3.2, the continuous clear width of pedestrian access routes shall be 1.2 m (4.0 ft) minimum, exclusive of the width of the curb....
-
225.2.2 Self-Service Shelving
Self-service shelves shall be located on an accessible route complying with 402. Self-service shelving shall not be required to comply with 308....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
2.5.5 Turning Space
Where resting intervals are provided adjacent to an outdoor recreation access route, a turning space complying with ABAAS section 304.3.2 shall be provided....
-
Surfaces for Outdoor Recreation Access Routes
The surface of an outdoor recreation access route and the surface surrounding constructed features must be firm and stable. No exceptions are allowed....
-
Elevators and Platform Lifts
limited application elevators (smaller, slower elevators used for low-traffic, low-rise facilities) or platform lifts that comply with ADAAG may be used instead of gangways as part of an accessible...
-
225.2.2 Self-Service Shelving
Self-service shelves shall be located on an accessible route complying with 402. Self-service shelving shall not be required to comply with 308....
-
1016.5 Obstacles
This section contains technical requirements for obstacles on outdoor recreation access routes, passing spaces, and resting intervals....
- Access Board: Multi User Toilet Room Layout
-
11B-225.2.2 Self-service shelving
Self-service shelves shall be located on an accessible route complying with Section 11B-402. Self-service shelving shall not be required to comply with Section 11B-308....
- Seton Directional Accessible Route Signs - Men's with ISA and Arrow
-
1134A.6, Item 4
Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....