The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....
Search Results "Wheelchair Storage Space"
Commonly Searched Documents
-
R404.7.2 Parallel Approach
-
Is clear floor space required to be centered on elements?
The standards require the clear floor space to be centered on wheelchair accessible drinking fountains (forward approach), kitchen work surfaces, (forward approach), and washers and dryers...
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
502.2 Vehicle Spaces
502.2 Vehicle Spaces. Each parking space must be at least 12 feet (3658 mm) wide shall be marked to define the width, and shall have an adjacent access aisle complying with 502.3....
-
808.3 Clear Floor Space
808.3 Clear Floor Space. Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
F244.2.3.2 Parking Spaces
Where provided, parking spaces shall comply with F244.2.3.2....
-
May a transit operator deny boarding to a rider whose wheelchair is difficult to secure?
If the transit operator has a policy that requires securement, or if a rider asks that the wheelchair be secured, Section 37.165(f) of the DOT ADA regulations requires transit personnel...
-
May a transit operator deny boarding to a rider whose wheelchair is difficult to secure?
If the transit operator has a policy that requires securement, or if a rider asks that the wheelchair be secured, Section 37.165(f) of the DOT ADA regulations requires transit personnel...
-
Breast Platform [M303.4.1]
Because this recommendation evolved from technologist experience on equipment with less knee space, disability advocates supported the rationale for 26 inches as the minimum....
-
Clear Floor Space
Clear floor spaces for inmates who use mobility devices...
-
11B-605.3 Clear floor space
11B-605.3 Clear floor space. A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
Accessible Parking Space
Accessible Parking Space...
-
808.3 Clear Floor Space
Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
808.3 Clear Floor Space
Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
5.1.6 Clear Floor or Ground Space
A clear floor or ground space at least 36 inches (915 mm) by 48 inches (1220 mm) shall be provided parallel to the entrance to the camp shelter....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
- Figure 604.8.1.2 Wheelchair Accessible Toilet Compartment Doors – Drawing from the U.S. Access Board
-
11B-703.8.7 Character spacing
11B-703.8.7 Character spacing. Spacing shall be measured between the two closest points of adjacent low resolution VMS characters within a message, excluding word spaces....
-
11B-703.8.7 Character spacing
11B-703.8.7 Character spacing. Spacing shall be measured between the two closest points of adjacent low resolution VMS characters within a message, excluding word spaces....
-
1002.6.1 Clear Floor or Ground Space
1002.6.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
§ 36.304(f) Selling or serving space
(f) Selling or serving space....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.1 General
Clear floor or ground space shall comply with 305....