5.4.5 Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and maximum vertical...
Search Results "Vertical Actuation Bar"
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
-
Permanently Installed Systems
Vertical wheelchair lifts are differentiated from elevators because they are limited in the height of their vertical lift, are not enclosed, and do not go through a floor level....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
RECOMMENDED CHANGE
RECOMMENDED CHANGE Revise the Section 5.4.11 recommendation as follows: The Committee recommends transfer supports and connections contain the strength to resist vertical forces of...
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
MEANS OF EGRESS
A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to a public way....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. ...
-
Automatic Operation [4.10.2]
Self-leveling must correct the overtravel or undertravel of a car as it stops at a landing within a ½ inch vertical tolerance since changes in level greater than ½ inch can be troublesome...
-
11B-404.2.7 Door and gate hardware
The lever of lever actuated latches or locks must be curved with a return to within ½ inch of the door to prevent catching on the clothing of persons during egress. ◼ [2010 ADA Standards...
-
11B-404.2.7 Door and gate hardware
The lever of lever actuated latches or locks must be curved with a return to within ½ inch of the door to prevent catching on the clothing of persons during egress. ◼ [2010 ADA Standards...
- American Specialties Heavy Duty Stainless Steel Soap Dish with Rectangular Solid Bar 0398
-
1. Federal Laws and Regulations
But, for example, if DOT regulations require that a truck have 3 grab bars in specified places, and an otherwise qualified individual with a disability could perform essential job functions...
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Gaps: ADA Standard Section 1002.4.3
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
11B-806.2.3.1 Personal lift device floor space
The clearance shall be parallel to the long side of the bed and extend under the bed to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (...
-
406.2.2 Clear height
While the minimum height is required to be 7'-0" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular...
-
Platform and Vehicle Floor Coordination: ADA Standard Section 810.5.3
In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192...
-
4.34.5.4(5) Shower unit
Figure 48 Location of Grab Bars and Controls of Adaptable Bathtubs...
- AJW Architectural Products UG3-Railing UG3X-Y108 108" Concealed Snap Flange, 1.5" Diameter, Peened Grip - Configuration Y
-
M305.3.2 Height
Horizontal standing support gripping surfaces shall comply with M305.3.2.1 and vertical standing support gripping surfaces shall comply with M305.3.2.2....