The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit. The angle of the water stream shall...
Search Results "Signage Height"
-
11B-602.6 Water flow
-
Service
Make sure accessible paths of travel are clearly marked with proper signage. Offer orientation to the facility layout for visually impaired customers....
-
609.4 Position of Grab Bars
The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1....
-
609.4 Position of Grab Bars
The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1....
-
11B-609.4 Position of grab bars
The height of the lower grab bar on the back wall of a bathtub shall comply with Section 11B-607.4.1.1 or 11B-607.4.2.1....
-
609.4 Position of Grab Bars
The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1....
-
11B-609.4 Position of grab bars
The height of the lower grab bar on the back wall of a bathtub shall comply with Section 11B-607.4.1.1 or 11B-607.4.2.1....
-
11B-609.4 Position of grab bars
The height of the lower grab bar on the back wall of a bathtub shall comply with Section 11B-607.4.1.1 or 11B-607.4.2.1....
-
11B-812.8.1 Four or fewer
Where four or fewer total EVCS are provided, identification with an International Symbol of Accessibility (ISA) shall not be required.
-
11B-202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction and shall comply with 11B-202.4. Advisory 11B-202.2 Additions. An...
-
11B-202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction and shall comply with 11B-202.4. Advisory 11B-202.2 Additions. An...
-
11B-812.8.1 Four or fewer
Where four or fewer total EVCS are provided, identification with an International Symbol of Accessibility (ISA) shall not be required.
-
609.4 Position of Grab Bars
The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1....
-
§ 38.123(a)(3)
mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height...
-
11B-707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
11B-707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
(1)(c)
closet, and a horizontal grab bar at least 40 inches (1015 mm) long should be mounted on at least one side wall, with one end not more than 12 inches (305 mm) from the back wall, at a height...
-
Facility
Knee and toe clearance complying with 306 shall be providing. (17” min. depth.) 902 Dining Surfaces and Work Surfaces. 902.3 Height....
-
Parking Signs
[See subsections ...]
-
1003.2.13 Accessible means of egress
Section 1003.2.13 Change to read as shown: (E19-00 & E20-00) 1003.2.13 Accessible means of egress. Accessible means of egress shall comply with Sections 1003.2.13.1 through...
-
1011.4, Item 3
3. Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be...
-
R211.4 Accessible Parking Space and Passenger Loading Zone Signs
R211.4 Accessible Parking Space and Passenger Loading Zone Signs. Accessible parking spaces and accessible passenger loading zones shall be identified by signs displaying the...
-
11B-812.8 Identification signs
EVCS identification signs shall be provided in compliance with Section 11B-812.8.