(1) A portion of a stairway landing within a smokeproof enclosure (complying with local requirements).
Search Results "Public Use Area"
Commonly Searched Documents
-
4.3.11.1(1)
-
1007.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
-
408.1 General
Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
11B-408.4.1 Car dimensions and doors
Existing elevator cars shall be permitted to provide a clear width 36 inches (915 mm) minimum, clear depth 54 inches (1370 mm) minimum, and a net clear platform area 15 square feet minimum...
-
11B-408.4.1 Car dimensions and doors
Existing elevator cars shall be permitted to provide a clear width 36 inches (915 mm) minimum, clear depth 54 inches (1370 mm) minimum, and a net clear platform area 15 square feet minimum...
-
FAQ: What are "Corada WorkGroups?"
Content may be marked so that it can be seen by other Corada users and the general public, however, by editing the 'privacy' settings....
-
§ 35.107(a) Designation of responsible employee
A public entity that employs 50 or more persons shall designate at least one employee to coordinate its efforts to comply with and carry out its responsibilities under this part, including...
- California Department of Fair Employment and Housing
-
Primary Consideration
Public entities are required to give primary consideration to the type of auxiliary aid or service requested by the person with the disability unless they can demonstrate that another equally...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
2. Adequate Space
Within the voting area, is adequate space available on the accessible level for check-in tables, a voting demonstration area (if provided), and at least one accessible voting station?...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
4.1.1(2) Application Based on Building Use
(2) Application Based on Building Use....
-
Section 36.202(c) (Section-By-Section Analysis and Response to Comments)
The intent of the contractual prohibitions of these paragraphs is to prohibit a public accommodation from doing indirectly, through a contractual relationship, what it may not do directly...
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
§35.130(b)(3)
(3) A public entity may not, directly or through contractual or other arrangements, utilize criteria or methods of administration:...
-
§ 35.130(b)(3)
(3) A public entity may not, directly or through contractual or other arrangements, utilize criteria or methods of administration:...
-
G2
[ADA Standards §§ 4.1.3(1), 4.3.8] Note: Although the facility survey cannot check the accessibility of the cots because they will not be installed until the shelter is in use, planning...
-
1007.9 Signage
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2....
-
1015.1 General
Viewing areas shall comply with 1015....
-
1015.1 General
Viewing areas shall comply with 1015....
-
§ 37.7(b)(1)(i)
(i) A public or private entity that provides transportation services and is subject to the provisions of subpart D or subpart E this part; or...
-
Elevated: ADA Standard Section 1008.2.5.2
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum.