REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over projections 11B-308.2.2/3.2...
Search Results "Flared Side"
-
Reach Ranges and Operable Parts
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
- Bobrick B-3091 ClassicSeries® Recessed-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
- Bobrick B-3092 ClassicSeries® Recessed-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
-
Detectable Warning Surfaces on Curb Ramps (Section-by-Section Analysis)
The Department of Transportation standards require detectable warning surfaces to extend the full width of the curb ramp (exclusive of flared sides) and either the full depth of the curb...
- SafePath EntryLevel™ Landings
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
11B-505.6 Gripping surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
11B-505.6 Gripping surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
- Hager Companies Door Protection Plate 204S
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
1014.2.1.1 Clear Ground Space
One full unobstructed side of the clear ground space shall adjoin or overlap an outdoor recreation access route or trail, as applicable, or another clear ground space....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
Toilet Rooms-Banquet Area
The toilet centerline of the men's toilet room is 19" from the side wall instead of the required 18". See Standards § 4.16.2....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Diagonal Curb Ramps [4.7.10]
In addition, a segment of straight curb at least 2 feet long must be provided on each side of the curb ramp and within the marked crossing....
-
1014.2.1.1 Clear Ground Space
One full unobstructed side of the clear ground space shall adjoin or overlap an outdoor recreation access route or trail, as applicable, or another clear ground space....
-
Clear Floor Space [§309.2]
If clear floor space is obstructed on both sides more than half the minimum required depth, a wider clearance (36” min.) is required for maneuvering and sway....
-
Thresholds [§404.2.5]
A maximum height of 3/4” is permitted for existing or altered thresholds if they have a beveled edge on each side with a slope not steeper than 1:2....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....