The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
Search Results "Water Closet"
Commonly Searched Documents
-
11B-604.9.3 Height
-
11B-604.5.2 Rear wall
location of a recessed fixture adjacent to the water closet. 2. ...
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
- Whitehall Mfg. Plumbing Solutions for the Modern Healthcare Environment
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
Willoughby Industries ETW-1490-FM-BS-HC Floor Mounted Blowout Series Water Closet
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Willoughby Industries ETW-1490-FM-TS-HC Floor Mounted Blowout Series Water Closet
Requires the Premium User plan or above. (Login or upgrade your account!)
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604 Water closets and toilet compartments
SECTION 11B-604 Water closets and toilet compartments 11B-604.3.2 Overlap....
-
11B-213.3.1 Toilet compartments
Corrects drafting error in prior code adoption to require that the fixture count for determining when additional accessible toilet compartments are required includes both water...
- Caroma® USA Somerton Smart 270 Easy Height Elongated Toilet
-
Water Play Components: ADA Standard Section 1008.2.3
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. Advisory 1008.2.3 Water Play Components....
-
1134A.7, Item 2
Where the water closet is placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
1134A.7, Item 2
Where the water closet is placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
- Caroma® USA Sydney Smart II Elongated Toilet
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
For the water closet clearance in single-user toilet rooms with the in-swinging door requirement (Req. #32), the expert panel determined that the primary beneficiaries would be persons who...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
For the water closet clearance in single-user toilet rooms with the in-swinging door requirement (Req. #32), the expert panel determined that the primary beneficiaries would be persons who...