(2) The accessible route required by 10.3.2(1) shall include the features specified in 10.3.1(1), (4)-(9), (11)-(15), and (17)-(19)....
Search Results "Vertical Access"
Commonly Searched Documents
-
10.3.2(2)
-
A4.1.3(5)
A4.1.3(5) Only full passenger elevators are covered by the accessibility provisions of 4.10....
-
Head Room [4.4.2]
Circulation paths must provide at least 80 inches of vertical clearance. Otherwise, fixed barriers detectable by canes must define areas with less clearance....
- Sesame Retractable Stairs with Lift
-
Do the exceptions for accessible routes between stories apply to facilities that are only partially occupied by entities not permitted the exception, such as health care facility or shopping center?
In mixed use facilities that otherwise qualify for this exception, an accessible route is required to serve each story containing occupancies not permitted the exception....
-
M305.3.1.3 Vertical Position
The length of the gripping surface on vertical standing supports shall be 18 inches (455 mm) minimum....
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface....
-
M305.3.2 Vertical Position
Where the support is vertical, it shall be 18 inches (455 mm) minimum in length and the bottom end of the support shall be 34 inches (865 mm) high minimum and 37 inches (940 mm) high maximum...
-
Location: ADA Standard Section 502.3.4
Section 502.3.4 covers the current ADA Standards for the required location of access aisles.
- Ascension Wheelchair Lift: Accessibility at the Brockville Arts Centre
-
407.8.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
407.12.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
407.8.2.2 Obstructed Side Reach
Where the operable part is located more than 10 inches (255 mm), but not more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches...
-
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis)
An unobstructed forward reach, for purposes of this section, occurs when the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference...
-
1017.8.4 Turning Space
This section requires a turning space complying with 304.2.3 of the Architectural Barriers Act Accessibility Guidelines where resting intervals are provided adjacent to the trail tread....
-
407.12.2.2 Obstructed Side Reach
Where the operable part is located more than 10 inches (255 mm), but not more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches...
-
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis)
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis) This section proposes that, where the operable part is located more than 10 inches, but not more than 24 inches, behind the vertical...
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
An obstructed forward reach, for purposes of this section, occurs when the operable part is located behind the leading edge of the maximum protrusion within the length of the vertical reference...
-
Private Sector Facilities (Places of Public Accommodation & Commercial Facilities)
An accessible route is not required to connect stories in a private sector facility (place of public accommodation or commercial facility subject to title III of the ADA) that is either...
-
407.8.3.2 Obstructed Forward Reach
Where the operable part is located beyond the leading edge of the maximum protrusion within the length of the vertical reference plane, the operable part shall conform to 407.8.3.2....
-
407.8.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220...
-
407.12.3.2 Obstructed Forward Reach
Where the operable part is located beyond the leading edge of the maximum protrusion within the length of the vertical reference plane, the operable part shall conform to 407.12.3.2....
-
407.12.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220...
-
ACCESS AISLE
[DSA-AC] An accessible space adjacent to or between vehicle spaces that provides clearances in compliance with this code....