Search Results "Means of Egress"
Commonly Searched Documents
- Trimco Hardware Lockdown Hardware Installation Walkthrough
- Allegion Von Duprin 98/99 Series Von Duprin CVC Traditional and Quick Adjust Bottom Latch Adjustment
- Trimco Hardware Lockdown Hardware Function Walkthrough
- Allegion Von Duprin 98/99 Series Adding a New Von Duprin QEL Plus to Your Existing EL Device Video
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
4.1.3(9)*
(9)* In buildings or facilities, or portions of buildings or facilities, required to be accessible, accessible means of egress shall be provided in the same number as required for exits...
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3....
-
1002.1 Definitions
The following terms are defined in Chapter 2: ACCESSIBLE MEANS OF EGRESS. AREA OF REFUGE. EXIT. GUARD ([DSA-AC, HCD 1 & HCD 2] or GUARDRAIL). HANDRAIL....
-
1002.1 Definitions
The following terms are defined in Chapter 2: ACCESSIBLE MEANS OF EGRESS. AREA OF REFUGE. EXIT. GUARD ([DSA-AC, HCD 1, HCD 2 & HCD 1-AC] or GUARDRAIL). HANDRAIL....
-
Accessible Means of Egress
This guide explains requirements in the ADA Standards and referenced sections of the International Building Code (IBC) and was developed in cooperation with the International...
-
1009.6.5 Two-way communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2.
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that...
-
Are exterior stairs required to comply with the Standards?
The Standards apply to both exterior and interior stairs that are part of a required means of egress....
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
Scoping [4.1.3(7)]
at each accessible entrance at least one door at each accessible space within a building or facility each door that is an element of an accessible route or an accessible means...
-
Automatic Door Break Out Openings
The 2010 Standards at sections 404.1, 404.3, 404.3.1, and 404.3.6 require automatic doors that are part of a means of egress and that do not have standby power to have a 32-inch minimum...
-
11B-404.3.2 Maneuvering clearance
Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with Section 11B-404.2.4....
-
F207.2 Platform Lifts
Supplement) or section 1007.5 of the International Building Code (2003 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1) to serve as a part of an accessible means...
-
1007.2, Item 8
8. Ramps complying with Section 1010, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable.
-
1007.2, Item 5
5. Elevators complying with Section 1007.4, and Chapter 11A, Section 1124A, or Chapter 11B, Sections 11B-206.6 and 11B-407, as applicable.
-
1009.15 Handrails
1009.15 Handrails. ... [DSA-AC] For applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, see Chapter 11B, Sections 11B-504.6...
-
1009.2, Item 8
8. Ramps complying with Section 1012, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable.
-
1009.2, Item 5
5. Elevators complying with Section 1009.4, and Chapter 11A, Section 1124A, or Chapter 11B, Sections 11B-206.6 and 11B-407, as applicable.
-
1011.11 Handrails
... [DSA-AC] For applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, see Chapter 11B, Sections 11B-504.6 and 11B-505.