Scoping [4.1.3(10)] ADAAG does not specify the number of fixtures a building must have. Instead it requires access based on the number provided on each floor so that half (50%)...
Search Results "High Energy Door"
Commonly Searched Documents
-
Scoping [4.1.3(10)]
-
One Unit Per Floor
One Unit Per Floor Where only one fixed unit is intended on a floor, dual access can be provided by: two separate units a combination "hi-lo" unit a fixed...
-
Exterior Sites
Exterior Sites Recommendation: The 50% scoping required for building interiors should be followed for exterior sites. Where only one unit is provided or where they are spaced at...
-
211 Drinking Fountains
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different 4.1.3(10)(a)...
-
11B-211.3 More than minimum number
Where more than the minimum number of drinking fountains specified in Section 11B-211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with...
-
11B-211.2 Minimum number
No fewer than two drinking fountains shall be provided. When provided, one drinking fountain shall comply with Sections 11B-602.1 through 11B-602.6, 11B-602.8 and 11B-602.9 and one...
-
11B-211.2 Minimum number
No fewer than two drinking fountains shall be provided. When provided, one drinking fountain shall comply with Sections 11B-602.1 through 11B-602.6, 11B-602.8 and 11B-602.9 and one...
-
11B-211.3 More than minimum number
Where more than the minimum number of drinking fountains specified in Section 11B-211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with...
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
- Besam SW200i-IG In Ground Swing Door Operator, Center Pivot, Double Door
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
3.3.16 Door Use
3.3.16 Door Use A total of 144 WhMD users completed door use tasks for at least one of the doors....
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADAS] 407.3.5 Door Delay. ...
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADAS] 407.3.5 Door Delay....
-
4.13.12* AUTOMATIC DOORS AND POWER-ASSISTED DOORS
If an automatic door is used, then it shall comply with American National Standard for Power-Operated Doors, ANSI A156.10-1979....