Exterior exit stairways complying with Sections 1007.3 and 1026 and serving levels other than the level of exit discharge, and Chapter 11A, Section 1115A, or Chapter 11B, Sections 11B-210...
Search Results "Exit Enclosure"
Commonly Searched Documents
-
1007.2, Item 4
-
1009.2, Item 4
Exterior exit stairways complying with Sections 1009.3 and 1027 and Chapter 11A, Section 1115A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable and serving levels other than...
-
1007.2, Item 7
Horizontal exits complying with Section 1025....
-
1009.2, Item 7
Horizontal exits complying with Section 1026....
-
Accessible Means of Egress: ADA Standard Section 207
Section 207 covers scoping requirements in the most current ADA Standards for accessible means of egress.
-
1007.6 Areas of refuge
Where an elevator lobby is used as an area of refuge, the shaft and lobby shall comply with Section 1019.1.8 for smokeproof enclosures except where the elevators are in an area of refuge...
-
1007.2, Item 2
Interior exit stairways complying with Sections 1007.3 and 1022, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.2, Item 2
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1007.2, Item 3
Interior exit access stairways complying with Sections 1007.3 and 1009.3, Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.2, Item 3
Exit access stairways complying with Sections 1009.3 and 1019.3 or 1019.4, Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.3.3 Area of Refuge
Exceptions: Areas of refuge are not required at exit access stairways where two-way communication is provided at the elevator landing in accordance with Section 1009.8....
- ADA Sign Depot Exit Stair Down Sign - 6" x 6" - Tactile Text and Grade 2 Domed Braille
-
11B-206.4.1 Entrances
All entrances shall comply with Section 11B-404. [2010 ADA Standards] 206.4.1 Public Entrances. In addition to entrances required by 206.4.2 through 206.4.9, at least 60 percent...
-
1003.2.13.5 Areas of refuge
Where an elevator lobby is used as an area of refuge, the shaft and lobby shall comply with Section 1005.3.2.5 for smokeproof enclosures except where the elevators are in an area of refuge...
-
4.1.6(1)(g)
(g) In alterations, the requirements of 4.1.3(9), 4.3.10 and 4.3.11 do not apply.
-
1009.3.2 Stairway width
The clear width of 48 inches (1219 mm) between handrails is not required for stairways accessed from a refuge area in conjunction with a horizontal exit....
-
11B-703.5.6 Height from finish floor or ground
Floor-level exit signs complying with Chapter 10, Section 1013.7 shall not be required to comply with Section 11B-703.5.6....
-
Are exterior stairs required to comply with the Standards?
This includes exterior stairs that are part of exit discharge (i.e., the path from an exit to a public way such as a street or alley)....
-
1007.7 Signage
At exits and elevators serving a required accessible space but not providing an approved accessible means of egress, signage shall be installed indicating the location of accessible means...
-
1003.2.13.6 Signage
At exits and elevators serving a required accessible space but not providing an approved accessible means of egress, signage shall be installed indicating the location of accessible means...
-
1003.2.13.2 Enclosed stairways
shall either incorporate an area of refuge within an enlarged floor-level landing or shall be accessed from either an area of refuge complying with Section 1003.2.13.5 or a horizontal exit...
-
Can People with Limited Mobility Use the Usable Circulation Path by Themselves?
Is There a Direct Exit to Grade (or a Ramp)?...
-
F207 Accessible Means of Egress
[See subsections ...]