Search Results "Exit Door"
Commonly Searched Documents
-
11B-207 Accessible means of egress
-
1011.4 Raised character and Braille exit signs
1011.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
1013.4 Raised character and Braille exit signs
1013.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
Are screen doors or storm doors considered “doors in series”?
No, screen or storm doors are not considered “doors in series” since they are part of the same doorway opening as the entry door....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
4.13.11* DOOR OPENING FORCE
The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
-
A4.13.11 Door Opening Force
Although some people cannot manage the allowable forces in this guideline and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
A4.13.11 DOOR OPENING FORCE
Although some people cannot manage the allowable force in this standard and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
Raised character and Braille exit signs
Raised character and Braille exit signs shall comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5....
-
404.2.4.2 Doorways without Doors or Gates
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors....
-
404.2.4.2 Doorways without Doors or Gates
Sliding Doors, and Folding Doors....
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
206.5 Doors, Doorways, and Gates
206.5 Doors, Doorways, and Gates. Doors, doorways, and gates providing user passage shall be provided in accordance with 206.5....
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
Egress Signage
Section 216.4 provides specific requirements for means of egress, including exit doors, areas of refuge, and directional signs....
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
1010.1.8 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
A4.17.5 Doors
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...