Identification and directional signs for public TTYs shall be provided in accordance with Section 11B-216.9.
Search Results "Evacuation Signage"
Commonly Searched Documents
-
11B-216.9 TTYs
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
A circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter, shall be located at entrances to women’s toilet and bathing facilities. The circle symbol shall contrast with the...
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
An equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward, shall be located at entrances to men’s toilet and bathing facilities....
- Takeform Fusion Signage Floor Directional Type B.2
-
I. EMERGENCY MANAGEMENT PROCEDURES AND POLICIES
Department of Justice’s ADA Best Practices Tool Kit for State and Local Government (“ADA Tool Kit”) to address ADA obligations of emergency management, including planning, preparedness, evacuation...
-
I. EMERGENCY MANAGEMENT PROCEDURES AND POLICIES
Department of Justice’s ADA Best Practices Tool Kit for State and Local Government (“ADA Tool Kit”) to address ADA obligations of emergency management, including planning, preparedness, evacuation...
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.1 Finish and contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
Signage
Signage Common Problem: For permanent rooms and spaces, identification signage is mounted in the wrong location and cannot be read by persons who are blind or have low vision....
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5. Where pictograms are provided as...
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
WAY FINDING
[See subsections ...]
-
WAY FINDING
[See subsections ...]
-
WAY FINDING
[See subsections ...]
-
WAY FINDING
[See subsections ...]
-
WAY FINDING
[See subsections ...]
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
Signage [4.6.4]
Additional signage can clarify this, which may be important in lots with only one accessible space since that space must be a van space....
-
1007.10 Directional signage
1007.10 Directional signage. ...
-
11B-502.6.4.1
The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide by 36...