The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
Search Results "Elevator Hall Call Button"
-
407.2.1.3 Clear Floor or Ground Space
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
HALL CALL CONSOLE
[DSA-AC] An elevator call user interface exclusive to a destination-oriented elevator system that requires the user to select a destination floor prior to entering the elevator car....
-
HALL CALL CONSOLE
[DSA-AC] An elevator call user interface exclusive to a destination-oriented elevator system that requires the user to select a destination floor prior to entering the elevator car....
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button....
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button....
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button....
-
Elevator Landing Requirements [§407.2]
Elevator Landing Requirements [§407.2]...
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2....
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2....
-
Limited-Use/Limited-Application Elevators, Destination-Oriented Elevators and Private Residence Elevators
Limited-Use/Limited-Application Elevators, Destination-Oriented Elevators and Private Residence Elevators....
-
11B-411.2.1 Hall call consoles
SECTION TITLE NOTES 11B-411.2.1 11B-411.2.1.2 11B-411.2.1.2.2 Hall call consoles....
-
Section I: Elevators
(§407.4.1) I3 Are hallway elevator call buttons 48" high or lower?...
-
11B-411.2.1.3.1 Keypad call console arrangement
Where keypad call consoles are provided, the display screen shall be located directly above the keypad....
-
11B-411.2.1.3.1 Keypad call console arrangement
Where keypad call consoles are provided, the display screen shall be located directly above the keypad....
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
Verify Electrical
11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls. 11B-308 Location of elevator...