The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
Search Results "Clear Width at Turn"
Commonly Searched Documents
-
Handrails: ADA Standard Section 1009.3.3
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
4.23.3 CLEAR FLOOR SPACE
An unobstructed turning space complying with 4.2.3 shall be provided within an accessible bathroom....
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
4.23.3* Clear Floor Space
An unobstructed turning space complying with 4.2.3 shall be provided within an accessible bathroom....
-
A4.2.1(1) Space Requirements for Wheelchairs
Most wheelchair users need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on....
-
A4.2.1(1) Space Requirements for Wheelchairs
Many persons who use wheelchairs need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on....
-
5.3.2 Turning Space and Clear Floor or Ground Space
Turning space and clear floor or ground space complying with 5.3 shall be provided at pit toilets....
-
5.3.2 Turning Space and Clear Floor or Ground Space
Turning space and clear floor or ground space complying with 5.3 shall be provided at pit toilets. ...
-
11B-803.2 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
A4.2.1(2) Space Requirements for Use of Walking Aids
Although people who use walking aids can maneuver through clear width openings of 32 in (815 mm), they need 36 in (915 mm) wide passageways and walks for comfortable gaits....
-
A4.2.1(2) Space Requirements for Use of Walking Aids
Although people who use walking aids can maneuver through clear width openings of 32 in (815 mm), they need 36 in (915 mm) wide passageways and walks for comfortable gaits....
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
Road Closure Drawings
Many forest roads are closed to motor vehicle traffic by gates or other types of barriers. Often, foot travel is allowed beyond the restriction device. When foot travel is encouraged...
-
1009.3.2 Stairway width
Stairways shall have a clear width of 48 inches (1219 mm) minimum between handrails....
-
Aisle: ADA Standard Section 904.3.1
Aisles shall comply with 403.
-
11B-904.3.1 Aisle
Aisles shall comply with Section 11B-403.
-
SECTION 1018 AISLES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
Door Swing: ADA Standard Section 304.4
Section 304.4 covers the current ADA Standards for doors swinging into turning spaces.
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.
-
11B-410.6 Doors and gates
End doors and gates shall provide a clear width 32 inches (813 mm) minimum. Side doors and gates shall provide a clear width 42 inches (1067 mm) minimum....