Provide minimum vertical clearance of 114 in (2895 mm) at accessible passenger loading zones and along at least one vehicle access route to such areas from site entrance(s) and exit(s)....
Search Results "Bus Loading Zone"
Commonly Searched Documents
-
4.6.5* Vertical Clearance
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-503.6 Identification
Identification Removes requirements for ISA sign at passenger loading zones....
-
11B-1008.2.6.2 Use zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition)....
-
11B-206.2.1 Site arrival points
At least one accessible route shall be provided within the site from accessible parking spaces and accessible drop-off and passenger loading zones; public streets and sidewalks; and public...
-
How are accessible passenger loading zone aisles to be marked?
The Standards require access aisles to be marked so as to discourage parking in them, but they do not specify how markings are to be provided. State or local codes and regulations...
-
H. Drop-off Area Height
H. Is the height of the covered passenger pickup/drop-off area at least 9'−6" to allow vans with raised roofs to use such area? [ADA Stds. 4.6.5] Yes __ No __ N/A __ Comments:...
-
B5. Curb Ramp
B5. Is a curb ramp provided between the vehicle pull up area and the access aisle (see figure above) or the access aisle and the accessible route (see figure on page 9) to the...
-
B. Passenger Drop-Off Areas
[See subsections ...]
-
Occupant Load
The number of persons for which the means of egress of a building or portion of a building is designed.
-
OCCUPANT LOAD
The number of persons for which the means of egress of a building or portion thereof is designed.
-
Connection: ADA Standard Section 810.2.3
Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with 402....
-
Problem
Problem: A passenger drop-off and loading zone is provided but there is no curb ramp between the vehicle area and the sidewalk leading to the accessible polling place entrance....
-
Dimensions: ADA Standard Section 810.2.2
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Typical Issues
An accessible drop-off area, also known as an accessible passenger loading zone, must have a level access aisle, adjacent and parallel to the vehicle space....
-
Bus Stop Pads
Specifications in 810.2 for bus stops applied to "bus stop pads" in the proposed rule....
-
11B-209.2.3 On-street bus stops
On-street bus stops shall comply with Section 11B-810.2 to the maximum extent practicable....
-
Load and Unload Areas: ADA Standard Section 234.2
Section 234.2 covers scoping requirements in the current ADA Standards for load and unload areas for amusement rides.
-
§ 37.131(a)(1) Bus
(1) Bus....
-
Floor and Ground Surfaces: ADA Standard Section 503.4
Section 503.4 covers the current ADA Standards for the floor and ground surfaces at passenger loading zones.
-
503.3.2 Length
Access aisles shall extend the full length of the vehicle pull-up spaces they serve.
-
503.3.1 Width
Access aisles serving vehicle pull-up spaces shall be 60 inches (1525 mm) wide minimum.
-
503.3.2 Length
Access aisles shall extend the full length of the vehicle pull-up spaces they serve.
-
503.3.1 Width
Access aisles serving vehicle pull-up spaces shall be 60 inches (1525 mm) wide minimum.