Eliminating Hazards [4.26.4] Handrails, grab bars, and adjacent surfaces cannot have any sharp or abrasive elements....
Search Results "Water Closet Grab Bar"
Commonly Searched Documents
-
Eliminating Hazards [4.26.4]
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
Accessible Plumbing Fixtures
The Board has added clarification that at least one water closet, lavatory, and bathtub or shower, where provided, must be accessible (807.2.4)....
-
4.1.6(3)(e)(ii)
., removal of a water closet in order to create a double-wide stall), either alternate stall (Fig.30(b)) may be provided in lieu of the standard stall....
-
607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
- Florestone 35-62H Barrier-Free Shower
-
11B-608.5.2 Standard roll-in type shower compartments
unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab...
-
Homemods.org
., grab bars, ramps), moving furnishings, changing where activities occur (e.g., sleeping on the first instead of second floor) and renovations (e.g., installing a roll-in shower)....
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
11B-213.3.1 Toilet compartments
In addition to the compartments required to comply with Section 11B-604.8.1, where six or more toilet compartments are provided, or where the combination of urinals and water closets totals...
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11. Toilet rooms and bathing facilities
Toilet rooms and bathing facilities (including water closets, toilet rooms and stalls, urinals, lavatories and mirrors, bathtubs, shower stalls, and sinks.) 4.22 Where provided in...
-
§ 38.107(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep maneuvering space shall be provided in front of the water...
-
§ 38.123(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches....
- Jacknob Corp. 6190 ADA Concealed Latch with Round Bar
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep maneuvering space shall be provided in front of the water...
-
Protocol C Heights Obtained
27.0 30.0 33.3 34.3 We compared the two groups for transfer heights to/from the wheelchair to a level platform with and without grab...
-
11B-608.5.3 Alternate roll-in type shower compartments
bar, but no higher than 48 inches (1219 mm) above the shower floor, with their centerline at 39 inches (991 mm) to 41 inches (1041 mm) above the shower floor....
-
11B-608.5.3 Alternate roll-in type shower compartments
bar, but no higher than 48 inches (1219 mm) above the shower floor, with their centerline at 39 inches (991 mm) to 41 inches (1041 mm) above the shower floor....
- Hager Companies Round Push/Pull Bar Set 140P
- Hager Companies Round Push/Pull Bar Set 139P