Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
11B-206.7.3 Incidental spaces
-
1. Clear Width
Do bathroom doors in accessible guestrooms allow at least 32" of clear passage width to accommodate persons who use wheelchairs, walkers and other mobility aids?...
- American Specialties Folding Shower Seat 8205-L
-
1134A.6, Item 1.1
1.1 The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or...
-
1134A.6, Item 1.1
The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or...
- Access-Able Designs Bariatric Shower Bench SH-430-3SDL
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
Best Practice Recommendations for Layout Planning
If accessible restrooms are not on the same floor, increase break times between sessions....
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
§ 38.95(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
-
Toilet and Bathing Rooms
The 2010 Standards do not indicate a preference for either rectangular or L-shaped seats in shower compartments....
-
4.5 Maneuvering Clearances
But, it is not clear, how the different standards define these turns. For example, when should one plan for a 360 degree turn as opposed to a 180 degree turn? ...
-
Spaces and Elements: ADA Standard Section 206.2.4
Section 206.2.4 covers the scoping requirements in the most current ADA Standards for accessible routes connecting spaces and elements within a building.
- Wingits Reversible L-shaped 26" x 22.5" Shower Seat
-
Scoping [4.1.2(4), 4.1.3(3)]
Requirements in 4.5 apply to accessible routes and spaces, including ramps, elevators, platform lifts, and clear floor space....
-
Re: 608.2.3 Alternate Roll-In Type Shower Compartments
What does a good alternate roll-in shower look like?...
-
11B-1003.3.2 Boarding pier clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1524 mm) wide minimum and shall extend the full length of the boarding pier....
-
1003.3.2 Boarding Pier Clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
-
1003.3.2 Boarding Pier Clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
- American Specialties Folding Shower Seat 8208-R