5.1.4 Transfer Surface Height Measurement. The transfer surface height should be measured from the floor to the highest point on the seat in an uncompressed state, inclusive of...
Search Results "Patient Toilet Room"
Commonly Searched Documents
-
5.1.4 Transfer Surface Height Measurement
-
11B-224.1.3 Range of accommodations
Accessible guest rooms or suites shall be dispersed among the various classes of sleeping accommodations to provide a range of options applicable to room sizes, costs, and amenities provided...
-
11B-224.1.3 Range of accommodations
Accessible guest rooms or suites shall be dispersed among the various classes of sleeping accommodations to provide a range of options applicable to room sizes, costs, and amenities provided...
-
11B-224.1.3 Range of accommodations
Accessible guest rooms or suites shall be dispersed among the various classes of sleeping accommodations to provide a range of options applicable to room sizes, costs, and amenities provided...
-
224.1.2 Guest Room Doors and Doorways
EXCEPTION: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with 806.2 shall not be required to comply with 404.2.3....
-
F224.1.2 Guest Room Doors and Doorways
EXCEPTION: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with 806.2 shall not be required to comply with 404.2.3....
-
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry
Platforms M303.2.2 Proposed Exception: The exception to the minimum width in M303.2.2 would apply where ramped surfaces are provided on the opposite sides of the raised platform so that patients...
- Visitability
-
Visible Alarms in Guest Rooms with Communication Features
Visible Alarms in Guest Rooms with Communication Features....
-
M301.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
Accessible Sports Facilities
provisions contained in ADAAG address elements commonly found within a sports facility, such as accessible vehicle parking spaces, exterior accessible routes, doors, assembly sections, and toilet...
- Access Board: Tactile Sign Visual Requirements
- Access Board: International Symbol of Accessibility (ISA) Technical Requirements
-
604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
5.8.1 Wheelchair Spaces on Raised Platforms Recommendations
5.8.1 Wheelchair Spaces on Raised Platforms Recommendations Description: Proposed section M303 provides technical criteria for diagnostic equipment used by patients seated in a wheelchair...
-
Bobrick ClassicSeries Recessed Sanitary Napkin Disposal and Toilet Tissue Dispenser B-3094 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Scope: ADA Standard Section 201.1
Section 201 discusses the scope of the ADA Standards.
-
Features of an Accessible Examination Room
Features of an Accessible Examination Room 1....
-
F206.2.14 Golf Facilities
In addition, accessible routes serving golf car rental areas; bag drop areas; course weather shelters complying with F238.2.3; course toilet rooms; and practice putting greens, practice...
-
206.2.15 Golf Facilities
In addition, accessible routes serving golf car rental areas; bag drop areas; course weather shelters complying with 238.2.3; course toilet rooms; and practice putting greens, practice teeing...
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
907.2.6.2.3 Smoke detectors
An approved automatic smoke detection system shall be installed throughout resident housing areas, including sleeping areas and contiguous day rooms, group activity spaces and other common...