II−5.5000 Historic preservation programs. Special program accessibility requirements and limitations apply to historic preservation programs. Historic preservation programs are...
Search Results "Medical Care Facility"
-
II-5.5000 Historic preservation programs
-
General: ADA Standard Section 208.3.1
Section 208.3.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for parking space locations.
-
§ 37.61 Public transportation programs and activities in existing facilities
[See subsections ...]
-
Scoping Requirements [F244.5, F245.4, F246.4, and F247.3.2]
An ORAR is a continuous, unobstructed path that is intended for pedestrian use and that connects accessible elements, spaces, and facilities within camping and picnic facilities and at viewing...
-
R101 Purpose (Section-by-Section Analysis)
R101 Purpose (Section-by-Section Analysis) The proposed guidelines contain scoping and technical requirements to ensure that facilities for pedestrian circulation and use located in the...
-
11B-232.2.1.3 Substitute cells
When alterations are made to specific cells, detention and correctional facility operators may satisfy their obligation to provide the required number of cells with mobility features by...
-
11B-232.2.1.3 Substitute cells
When alterations are made to specific cells, detention and correctional facility operators may satisfy their obligation to provide the required number of cells with mobility features by...
-
Areas of sport activity. (Section-by-Section Analysis)
For purposes of the program accessibility requirement, as with play areas and swimming pools, where an existing facility provides multiple areas of sport activity that serve the same purpose...
-
F202.1 General
Additions and alterations to existing buildings or facilities, including leased buildings or facilities, shall comply with F202....
-
2. Standing Supports
received two comments, one of which addressed standing supports on mammography equipment (discussed above in Section IV.D.1 (Significant Changes – Standing Supports)) and one commenter (medical...
-
11B-249.1.1
Where adult changing facilities are provided, each adult changing facility shall comply with Section 11B-813....
- The GRIT Freedom Chair
-
Introduction
For example, the Federal Family and Medical Leave Act (FMLA) requires employers with 50 or more employees to provide up to 12 weeks of leave per year to eligible employees....
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
A medical association asserted that to the best of their knowledge, imaging equipment already meets the Wheeled Mobility Anthropometry Project recommendations....
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303.
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum. EXCEPTION: Wheelchair spaces located on raised platforms shall be permitted to be 32 inches (815 mm) wide minimum to a...
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.4 Components
Where components of diagnostic equipment are used to examine specific body parts, the components shall be capable of examining the body parts of a patient seated in a wheelchair....
-
M303.2.4 Equipment Clearances
Where wheelchair spaces are entered from the rear and includes space beneath components, wheelchair spaces shall include knee and toe clearances complying with M303.2.4.1 for breast...
-
M303.3.2 Beveled (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes greater than ¼ inch but not greater than ½ inch would be required...
-
M303.2.2 Width (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients seated in a wheelchair provide a wheelchair space that was at least 36 inches wide. There were no public...
-
M303.3.1 Vertical (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes of up to ¼ inch high are permitted to be vertical. This provision...
-
M303.4 Components (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair which has components that are used to examine specific body parts, be capable of...