An accessible entrance must provide at least one accessible door with maneuvering space, accessible door hardware, and enough clear width to allow people who use crutches, a cane, walker...
Search Results "Maneuvering Clearance (Alcove)"
Commonly Searched Documents
-
Typical Issues
-
Obstructions [4.7.8]
Space is needed at the top and bottom of ramps so that people using wheelchairs can align with the running slope and maneuver from ramps, including when making turns (which is difficult...
- Don-Jo Mfg., Inc. Pull Plate 7011
- Bobrick MatrixSeries Seat-Cover Dispenser B-5221
-
704.5 TTY Shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
4.2.6* SIDE REACH
If the side reach is over an obstruction, the reach and clearances shall be as shown in Fig. 6(c). Figure 6 Side Reach...
- Pilot Rock WXT and WXTH Picnic Table Using Aluminum
- Pilot Rock WUT and WUTH Picnic Table - Using Aluminum
- GPK Modular QuadDesk
- Bobrick Recessed Paper Towel Dispenser B-318
- Bobrick ConturaSeries Surface-Mounted Seat-Cover Dispenser B-4221
-
410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
Furnishings and Equipment
In addition, placement of non-fixed elements can affect the accessibility of an area by encroaching into accessible routes and clearances....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
11B-608.2.3 Alternate roll-in type shower compartments
FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE...
-
1009.4.1 Clear Deck Space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
Post-Mounted Objects [§307.3]
The 12” limit also applies to the clearance between multiple posts (excluding the sloping portions of handrails)....
-
Handrails [ADA Standards §504.6, §505]
Handrails [ADA Standards §504.6, §505] Specifications in the ADA Standards for handrail surfaces and clearances facilitate a power grip along the handrail length....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
11B-1009.4.1 Clear deck space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
§ 38.125(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a seating location...