Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3.
Search Results "Elongated Water Closet Seat"
Commonly Searched Documents
-
M303.3 Entry
-
M303.2.4.2.1 Depth
Wheelchair spaces shall include knee and toe clearance 17 inches (430 mm) deep minimum and 25 inches (635 mm) deep maximum.
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the...
-
11B-221.2.1.2 Luxury boxes, club boxes, and suites in arenas, stadiums, and grandstands
In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with Section 11B-802.1 shall be provided in accordance with Table...
-
M303.3 Entry (Section-by-Section Analysis)
This is an introductory section.
-
5.8.1 Wheelchair Spaces on Raised Platforms
5.8.1 Wheelchair Spaces on Raised Platforms.
-
M303.3 Entry
Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3.
-
§ 35.151(g) Assembly areas
(g) Assembly areas. Assembly areas subject to the proposed standards shall comply with the provisions applicable to assembly areas, including, but not limited to, sections 221 and...
-
§ 35.151(g) Assembly areas.
(g) Assembly areas. Assembly areas subject to this section shall comply with the provisions of the 2010 Standards applicable to assembly areas, including, but not limited to,...
-
5.4.3 Transfer Support Height for M301 and M302
would be an appropriate height for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
Height
would be an appropriate height for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
a. Knee and Toe Clearance
The requirements are intended to ensure that there is adequate space for a patient seated in a wheelchair to position underneath the equipment and align themselves against the breast platform...
-
Section 36.406(f) Assembly Areas (Section-by-Section Analysis)
These platforms cover groups of conventional seats and are used to provide groups of wheelchair seats and companion seats....
-
5.8.2.4 Unobstructed Floor Space Recommendation
In order to image as much of the breast as possible, patients cannot be seated in the “natural” sitting position....
-
Cross Section of Gripping Surfaces
appropriate for the gripping surfaces of transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
Clear Space Evaluation
Increasing the width of the clear floor space an additional 12 inches to 72 inches would accommodate 75-77% of users who would be expected to transfer higher or lower than their seat to...
-
Bradley Security Grab Bars Model SA70 Series
Requires the Premium User plan or above. (Login or upgrade your account!)
-
5.8.2.5 Toe Height Recommendation
However, it is important to provide extra toe space for patients who are seated close to the ground but have their footrests positioned at more of an angle....
-
(1) Adjustability: Minimum High Transfer Height
Seat heights for males were typically higher than for females....
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
and Toe Clearance Recommendations under Breast Platform Recommendations Description: The knee and toe clearance under the breast platform applies to mammography equipment for patients seated...
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
Clearances Around Gripping Surfaces
gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...