Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground....
Search Results "AHJ: Authority Having Jurisdiction"
Commonly Searched Documents
-
Refrigerator/Freezer: ADA Standard Section 804.6.6
-
Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms: ADA Standard Section 213.2.1
Section 213.2.1 covers scoping requirements in the current ADA Standards for unisex (single-use or family) toilet and unisex bathing rooms.
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 10 MEANS OF EGRESS
ETA Editor's Note Sections from California Building Code Chapter 10 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-233.3.2.1 Buyer identified residential dwelling units for sale
In such programs, the covered entity must provide the units that comply with the requirements for accessible features to those pre-identified buyers with disabilities who have requested...
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
CHAPTER 2 DEFINITIONS
ETA Editor's Note Sections from California Building Code Chapter 2 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
16) Elevator hoistway floor designations and car controls
16) Elevator hoistway floor designations and car controls ADAAG: Must have raised and brailled characters (§§4.10.5; 4.10.12)....
-
Providing Background Information to People with Sensory Disabilities
This not only serves as an ice-breaker, but also lets people who are blind or have low vision know who is at the meeting....
-
How do I know if I am protected by the ADA?
This means that you must have a disability as defined by the ADA....
-
Section 4.26.2
• Section 4.26.2 of the 1991 Standards requires handrail gripping surfaces to have a diameter of 1 ¼ inches to 1 ½ inches, or to provide an equivalent gripping surface....
-
907.2.6.2.2 Manual fire alarm boxes
Manual fire alarm boxes are not required to be located in accordance with Section 907.3 where the fire alarm boxes are provided at staff-attended locations having direct supervision over...
-
§100.20 Familial status
Familial status means one or more individuals (who have not attained the age of 18 years) being domiciled with— (a) A parent or another person having legal custody of such individual...
-
4.7.10 Diagonal Curb Ramps
If diagonal (or corner type) curb ramps have returned curbs or other well-defined edges, such edges shall be parallel to the direction of pedestrian flow....
-
There Are No “The Disabled” And There Is No “One Size Fits All.”
People with disabilities have the same range of personality traits, interests, and desires as everyone else. People with disabilities are a part of the world’s diversity....
-
Discussion
They like having information available on museum websites that is downloadable to their own assistive technology devices....
-
CHAMPIONS OF CHANGE: 23rd Anniversary of the Americans with Disabilities Act
Requires the Registered User plan or above. Login!
- Dyson Airblade V Hand Dryer Informational Video
- Better Living Signature Soap and Shower Dispenser 2
- Taylor ADA BLue-Lever™ Stand
-
Section 4.26.4
• Section 4.26.4 of the 1991 Standards requires handrail gripping surfaces to have edges with a minimum radius of 1/8 inch....