Platform lifts shall be permitted as a component of an accessible route in new construction in accordance with F206.7....
Search Results "Permitted Transfer"
Commonly Searched Documents
-
F206.7 Platform Lifts
-
503.4 Floor and Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
§ 38.103(a)
(a) Each car shall be equipped with an interior public address system permitting transportation system personnel, or recorded or digitized human speech messages, to announce stations and...
-
§ 38.87(a)
(a) Each vehicle shall be equipped with an interior public address system permitting transportation system personnel, or recorded or digitized human speech messages, to announce stations...
-
1.1.9 Effective date of this code
Only those standards approved by the California Building Standards Commission that are effective at the time an application for building permit is submitted shall apply to the plans and...
-
1.1.9 Effective date of this code
Only those standards approved by the California Building Standards Commission that are effective at the time an application for building permit is submitted shall apply to the plans and...
-
11B-404.2.4.4 Floor or ground surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exceptions: Reserved....
-
§ 382.21 Aircraft accessibility
This lavatory shall permit a qualified individual with a disability to enter, maneuver within as necessary to use all lavatory facilities, and leave, by means of the aircraft’s on-board...
-
Sec. 469.102(d)
(d) A public official of a political subdivision who is legally authorized to issue building construction permits may not accept an application for a building construction permit for a building...
-
11B-503.4 Floor and ground surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted...
-
11B-503.4 Floor and ground surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
1009.5 Platform lifts
Platform lifts shall be permitted to serve as part of an accessible means of egress where allowed as part of a required accessible route in Chapter 11A, Sections 1121A and 1124A.11, or Chapter...
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
11B-809.5.5.2 Identification
Such peepholes can be placed at a standard height and permit a view from several feet from the door. ◼...
-
11B-809.9.3 Removable base cabinets
Exception: Removable base cabinets shall be permitted under sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the...
-
Ask Questions and Provide Instructions
If you are transferring planes, you may want to investigate whether your trip involves more than one carrier....
-
11B-240.2.2 Elevated play components
For purposes of this section, ramps, transfer systems, steps, decks, and roofs are not considered elevated play components....
-
503.4 Floor and Ground Surfaces
Changes in level are not permitted. [ECTCR UFAS 4.6.5] EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
- Norton Surface Mounted Heavy Duty 9500 Series Door Closer
-
§ 38.95(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
§ 38.83(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
§ 38.125(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
503.4 Floor and Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....